AIR SWITCHING VALVE (for Bank 1) > REMOVAL |
| 1. REMOVE AIR CLEANER CAP AND HOSE |
![]() |
Remove the air cleaner cap and hose.
Disconnect the mass air flow meter connector, vacuum hose and ventilation hose and detach the 4 clamps.
Loosen the clamp.
Detach the 4 hook clamps, and then remove the air cleaner cap and hose.
| 2. REMOVE AIR CLEANER CASE SUB-ASSEMBLY |
Remove the air cleaner filter element.
![]() |
Remove the 2 bolts and air cleaner case.
| 3. REMOVE AIR TUBE |
![]() |
Remove the 2 bolts, 2 nuts and air tube.
Remove the 2 gaskets from the air tube.
| 4. REMOVE EMISSION CONTROL VALVE SET |
![]() |
Disconnect the emission control valve set connector.
Disconnect the air hose from the emission control valve set.
![]() |
Remove the 3 nuts and emission control valve set.