Home › ENGINE ยท 1UR-FE › ENGINE CONTROL SYSTEM › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSTALLATION

for Preparation Click here


HINT:
Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).



1. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)

HINT:
Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).



    A215448
  1. Install the heated oxygen sensor to the front exhaust pipe assembly by hand.



    A215449E02
  1. Using SST, tighten the heated oxygen sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). When using a torque wrench with a fulcrum length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and the wrench are connected in a straight line.

  1. Attach the 2 clamps and connect the the heated oxygen sensor connector.



2. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

HINT:
Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).



    A215445
  1. Install the heated oxygen sensor to the front No. 2 exhaust pipe assembly by hand.



    A215446E02
  1. Using SST, tighten the heated oxygen sensor.
    Text in Illustration 
    *a
    Fulcrum length

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). When using a torque wrench with a fulcrum length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and the wrench are connected in a straight line.

  1. Connect the heated oxygen sensor connector.



3. INSTALL PROPELLER SHAFT HEAT INSULATOR


C158452
  1. Install the heat insulator to the heat insulator bracket with the 2 bolts.

    Torque:
    16 N*m{ 160 kgf*cm , 12 ft.*lbf }



4. INSPECT FOR EXHAUST GAS LEAK

HINT:
If an exhaust gas leak has been repaired, perform an inspection following the repair (Click here).

If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.