Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1UR-FE EMISSION CONTROL

1UR-FE EMISSION CONTROL > SERVICE DATA



EGR VALVE:

Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
18 to 22 Ω
2 - 3
4 - 5
5 - 6


AIR PUMP (Standard Current):

Condition
Specified Condition
20°C (68°F)
10 to 40 A


AIR PUMP (Standard Resistance):

Tester Connection
Condition
Specified Condition
1 (APH+) - 3 (APHG)
-20°C (-4°F)
4.4 to 20.0 Ω
-10°C (14°F)
3.9 to 18.0 Ω
0°C (32°F)
3.5 to 16.0 Ω
10°C (50°F)
3.2 to 15.0 Ω
20°C (68°F)
3.0 to 14.0 Ω


AIR SWITCHING VALVE (for Bank 1):

Tester Connection
Condition
Specified Condition
1 - 5
20°C (68°F)
4.5 to 5.5 Ω
1 - Body ground
Always
1 MΩ or higher
5 - Body ground


AIR SWITCHING VALVE (for Bank 2):

Tester Connection
Condition
Specified Condition
1 - 5
20°C (68°F)
4.5 to 5.5 Ω
1 - Body ground
Always
1 MΩ or higher
5 - Body ground


PURGE VALVE:

Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
23 to 26 Ω
1 - VSV body ground
Always
10 MΩ or higher
2 - VSV body ground
10 MΩ or higher