1UR-FE EMISSION CONTROL > SERVICE DATA |
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 18 to 22 Ω |
| 2 - 3 | ||
| 4 - 5 | ||
| 5 - 6 |
| Condition | Specified Condition |
| 20°C (68°F) | 10 to 40 A |
| Tester Connection | Condition | Specified Condition |
| 1 (APH+) - 3 (APHG) | -20°C (-4°F) | 4.4 to 20.0 Ω |
| -10°C (14°F) | 3.9 to 18.0 Ω | |
| 0°C (32°F) | 3.5 to 16.0 Ω | |
| 10°C (50°F) | 3.2 to 15.0 Ω | |
| 20°C (68°F) | 3.0 to 14.0 Ω |
| Tester Connection | Condition | Specified Condition |
| 1 - 5 | 20°C (68°F) | 4.5 to 5.5 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 5 - Body ground |
| Tester Connection | Condition | Specified Condition |
| 1 - 5 | 20°C (68°F) | 4.5 to 5.5 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 5 - Body ground |
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
| 1 - VSV body ground | Always | 10 MΩ or higher |
| 2 - VSV body ground | 10 MΩ or higher |