DTC P144C Open in Secondary Air Injection System Heater Control Circuit |
DTC P144D Short in Secondary Air Injection System Heater Control Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| P144C | Open or short in the air pump heater (AI-HTR) relay circuit for 5 seconds (1 trip detection logic). |
|
| P144D | Open or short in the air pump heater (AI-HTR) relay circuit for 5 seconds (1 trip detection logic). |
|
| Related DTCs | P144C: Air pump heater relay circuit range check (Low voltage) P144D: Air pump heater relay circuit range check (High voltage) |
| Required Sensors/Components (Main) | Air pump heater relay (AI-HTR) |
| Required Sensors/Components (Related) | - |
| Frequency of operation | Continuous |
| Duration | 5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not stored | None |
| Current air pump heater relay (AI-HTR) | ON |
| Last air pump heater (AI-HTR) relay | ON |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Monitor runs whenever following DTCs not stored | None |
| Current air pump heater (AI-HTR) relay | OFF |
| Last air pump heater (AI-HTR) relay | OFF |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Air pump heater (AI-HTR) relay output terminal voltage | Low |
| Air pump heater (AI-HTR) relay output terminal voltage | High |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT AIR PUMP HEATER (AI-HTR) RELAY |
![]() |
Remove the air pump heater (AI-HTR) relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK AIR PUMP HEATER (AI-HTR) RELAY (POWER SOURCE) |
![]() |
Remove the air pump heater (AI-HTR) relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (Air pump heater (AI-HTR) relay) - Body ground | Always | 11 to 14 V |
| *1 | Engine Room Relay Block |
| *2 | Air Pump Heater (AI-HTR) Relay |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (ECM - AIR PUMP HEATER (AI-HTR) RELAY) |
Remove the air pump heater (AI-HTR) relay from the engine room relay block.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (Air pump heater (AI-HTR) relay) - D74-60 (HAI1) | Always | Below 1 Ω |
| 2 (Air pump heater (AI-HTR) relay) or D74-60 (HAI1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||