Home › Engine / Hybrid System › M15A-FKS (STARTING) › STARTING SYSTEM › from 2021.07
NM3700E _51 Engine / Hybrid System _094240 M15A-FKS STARTING _0443921 STARTING SYSTEM GE GENERAL F

M15A-FKS STARTING  STARTING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

A planetary type starter assembly is used.


b.

An Inrush Current Reduction (ICR) relay, which is built into the planetary type starter assembly, is used. The ICR relay stabilizes the vehicle power source voltage during starter motor operation. (Models with stop and start system)


c.

A starter control (cranking hold function) is used. Once the ignition switch is pushed, this function operates the starter until the engine starts. (Models with entry and start system)



SPECIFICATION


TMMF Made
Item Specification

*1: Length from the mounted area to the rear end of the starter.

*2: Viewed from pinion side.

Starter Type Planetary Planetary (Built-in ICR Relay)
Rating Output 1.0 kW 1.2 kW
Rating Voltage 12 V 12 V
Length*1 127.4 mm (5.02 in.) 127.4 mm (5.02 in.)
Weight 2150 g (4.7 lb.) 2800 g (6.2 lb.)
Rotational Direction*2 Clockwise Clockwise

TMC Made
Item Specification

*1: Length from the mounted area to the rear end of the starter.

*2: Viewed from pinion side.

Starter Type Planetary
Rating Output 1.0 kW
Rating Voltage 12 V
Length*1 127.4 mm (5.02 in.)
Weight 2150 g (4.7 lb.)
Rotational Direction*2 Clockwise