Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2021.07
NM3700E _58 Vehicle Interior _094254 HEATING / AIR CONDITIONING _0443877 AIR CONDITIONING SYSTEM GE GENERAL F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

A single zone automatic air conditioning system, dual zone automatic air conditioning system (left and right independent control) or manual air conditioning system is available depending on the model.


b.

HFC-134a or HFO-1234yf refrigerant is used depending on the models.



SPECIFICATION


a.

Ventilation and Heater Core

*1: Models with automatic air conditioning system

*2: Models with manual air conditioning system

Heater Radiator Unit Sub-assembly Type Straight Flow Aluminum (SFA) - II
Size (W x H x L) mm (in.) 180.7 x 120 x 27
(7.1 x 4.7 x 1.1)
Blower with Fan Motor Sub-assembly Motor Type DC Ferrite Brushless*1
DC*2
Fan Type Semi Sirocco
Fan Size (Dia. x H) mm (in.) 137.0 x 70 (5.4 x 2.8)


b.

Air Conditioning

*1: Gasoline models

*2: Hybrid models

*3: Models using HFO-1234yf refrigerant

*4: Models using HFC-134a refrigerant

*5: Models without stop and start system

*6: Models with stop and start system

Cooler Condenser Assembly Type Global Inner-fin Condenser (GIC)
Size (W x H x L) mm (in.) 530 x 376.2 x 11.5 (20.9 x 14.8 x 0.5)*1
630 x 376.2 x 11.5 (24.8 x 14.8 x 0.5)*2
Fin Pitch mm (in.) 2.5 (0.10)
Compressor Assembly with Pulley*1 5TSE10
Compressor with Motor Assembly*2 ESB20C
Refrigerant Type HFO-1234yf (R1234yf)*3
HFC-134a (R-134a)*4
Evaporator Type Beneficial Refrigerant Stream (BRS) Evaporator*5
Cold-Storage (CS) Evaporator*6
Size (W x H x L) mm (in.) 199.3 x 231.0 x 38.0 (7.8 x 9.1 x 1.5)
Fin Pitch mm (in.) 3.0 (0.12)



MAIN FEATURES


a.

The air conditioning system has the following features:

*1: Models with automatic air conditioning system

*2: Models with manual air conditioning system

*3: Gasoline models

*4: Models with rear heater duct

*5: Models with stop and start system

*6: Models with PTC heater

High Performance
·

A high efficiency type clean air filter, which has a pollen removal effect, is used.

·

The blower control has 7 levels in manual mode and 31 levels in auto mode for more precise control.*1

·

The blower control has 4 levels.*2

·

Neural network control is used so passengers can finely control the air conditioning for maximum comfort.*1

·

Using the following features of the compressor (continuously variable capacity compressor), high cooling performance and a quiet cabin have been achieved:*3

-

Oil Separator

-

Variable Suction Side Throttle

-

Solenoid Valve with Built-in Crank Chamber to Suction Passage (CS) Valve


·

The rear outlet is installed under the driver's seat and under the passenger seat to ensure a comfortable rear passenger cooling performance.*4

·

The Positive Temperature Coefficient (PTC) heater control is used. This system contains a PTC heater (quick heater assembly) that heats the air that has passed through the heater radiator unit sub-assembly to ensure proper heater performance.*6


Lightweight
·

An air conditioning harness assembly with a built-in communication/driver IC is used in a lightweight wire harness design to allow a reduced number of wires.*1

·

The use of this type of connector means that pulse pattern type servo motors can be used.*1


Compact A blower motor with a built-in blower motor controller is used to achieve a compact construction.*1
Others The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.
·

Semi-center Location Air Conditioning Unit

·

Straight Flow Aluminum (SFA)-II Heater Radiator Sub-assembly

·

Global Inner-fin Condenser (GIC) Sub-cool Condenser

·

Beneficial Refrigerant Stream (BRS) Evaporator

·

Cold Storage Evaporator*5





PRECAUTION


a.

Precaution for Refrigerant HFO-1234yf

i.

Always use HFO-1234yf as the refrigerant.

CAUTION:
·

Do not charge the system with refrigerant near open flames, as HFO-1234yf is combustible.

·

When charging the system with refrigerant, make sure the area is well ventilated (especially be careful in areas where the gas can easily accumulate such as under lifts and in garage pits, as the gas is heavier than air).

·

Follow any local regulations regarding combustible gases.

·

Be sure to use a refrigerant recovery unit that is compatible with HFO-1234yf systems.



HINT:

The shape of the service port for refrigerant charging has an exclusive design conforming to international standards for HFO-1234yf to prevent improper refrigerant charging.