88719A
1.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Automatic Air Conditioning System)
Pre-procedure1
Connect the A51 air conditioner pressure sensor connector.
Install a manifold gauge set.
Turn the A/C switch ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H23)Location & Routingewd_type=routing;type=c;code=H23 Click Connector(H23)Instrument Panel>Instrument Panel Wire / Speaker Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=H23;pinno=36,12 |
||
| H23-36 (PRE) - H23-12 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.62 to 4.73 V |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
If the voltage is not as specified, replace the air conditioner pressure sensor.
Post-procedure1
Turn the ignition switch off.
Pre-procedure2
Disconnect the A51 air conditioner pressure sensor connector.
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure2
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
| *b | Component without harness connected
(Air Conditioning Amplifier Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A51,H25)Location & Routingewd_type=routing;type=c,c;code=A51,H25 Click Connector(A51)Engine Compartment>Engine Room Main Wire>Air Conditioning Pressure Sensorewd_type=component;type=c;code=A51;pinno=1,2,3 Click Connector(H25)Instrument Panel>Instrument Panel Wire / Speaker Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=H25;pinno=15,6,11 |
||
| A51-1 (-) - H25-15 (SG-4) | Always | Below 1 Ω |
| A51-2 (PR) - H25-6 (PRE) | Always | Below 1 Ω |
| A51-3 (+) - H25-11 (S5-3) | Always | Below 1 Ω |
| A51-1 (-) - Body ground | Always | 10 kΩ or higher |
| H25-15 (SG-4) - Body ground | Always | 10 kΩ or higher |
| A51-2 (PR) - Body ground | Always | 10 kΩ or higher |
| H25-6 (PRE) - Body ground | Always | 10 kΩ or higher |
| A51-3 (+) - Body ground | Always | 10 kΩ or higher |
| H25-11 (S5-3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Post-procedure2
None.
Pre-procedure3
Connect the H25 air conditioning amplifier assembly connector.
Turn the ignition switch ON (IG).
Procedure3
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A51)Location & Routingewd_type=routing;type=c;code=A51 Click Connector(A51)Engine Compartment>Engine Room Main Wire>Air Conditioning Pressure Sensorewd_type=component;type=c;code=A51;pinno=3 |
||
| A51-3 (+) - Body ground | IG ON | 4.75 to 5.25 V |
If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
Post-procedure3
None.
Pre-procedure4
Connect the A51 air conditioner pressure sensor connector.
Turn the A/C switch ON.
Procedure4
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H25)Location & Routingewd_type=routing;type=c;code=H25 Click Connector(H25)Instrument Panel>Instrument Panel Wire / Speaker Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=H25;pinno=6,15 |
||
| H25-6 (PRE) - H25-15 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.62 to 4.73 V |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
If the voltage is not as specified, replace the air conditioner pressure sensor.
Post-procedure4
None.
88719A
2.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Manual Air Conditioning System)
Pre-procedure1
Disconnect the A51 air conditioner pressure sensor connector.
Disconnect the H23 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
*b | Component without harness connected
(Air Conditioning Amplifier Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A51,H23)Location & Routingewd_type=routing;type=c,c;code=A51,H23 Click Connector(A51)Engine Compartment>Engine Room Main Wire>Air Conditioning Pressure Sensorewd_type=component;type=c;code=A51;pinno=1,2,3 Click Connector(H23)Instrument Panel>Instrument Panel Wire / Speaker Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=H23;pinno=12,36,11 |
||
| A51-1 (-) - H23-12 (SG-4) | Always | Below 1 Ω |
| A51-2 (PR) - H23-36 (PRE) | Always | Below 1 Ω |
| A51-3 (+) - H23-11 (S5-3) | Always | Below 1 Ω |
| A51-1 (-) - Body ground | Always | 10 kΩ or higher |
| H23-12 (SG-4) - Body ground | Always | 10 kΩ or higher |
| A51-2 (PR) - Body ground | Always | 10 kΩ or higher |
| H23-36 (PRE) - Body ground | Always | 10 kΩ or higher |
| A51-3 (+) - Body ground | Always | 10 kΩ or higher |
| H23-11 (S5-3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Post-procedure1
None.
Pre-procedure2
Connect the H23 air conditioning amplifier assembly connector.
Turn the ignition switch ON (IG).
Procedure2
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A51)Location & Routingewd_type=routing;type=c;code=A51 Click Connector(A51)Engine Compartment>Engine Room Main Wire>Air Conditioning Pressure Sensorewd_type=component;type=c;code=A51;pinno=3 |
||
| A51-3(+) - Body ground | IG ON | 4.75 to 5.25 V |
Post-procedure2
None.