CUSTOMIZE AIR CONDITIONING SYSTEM
Customizing with the GTS.
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
The following items can be customized.
Select the setting by referring to the table below.
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Evaporator Control | Function to set the evaporator control to the automatic position (Automatic) to save power or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up | Automatic | $00:Manual,$01:Automatic | Air conditioning amplifier assembly |
| Refrigerant Shortage Check | Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |