Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for HV Model)
RM3700E _58 Vehicle Interior _093020 HEATING / AIR CONDITIONING _0438859 AIR CONDITIONING SYSTEM(for HV Model) W

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  CUSTOMIZE PARAMETERS  


CUSTOMIZE AIR CONDITIONING SYSTEM


a.

Customizing with the GTS.

NOTICE:
·

When the customer requests a change in a function, first make sure that the function can be customized.

·

Be sure to make a note of the current settings before customizing.

·

When troubleshooting a function, first make sure that the function is set to the default setting.



HINT:

The following items can be customized.


i.

Select the setting by referring to the table below.

Air Conditioner
Tester Display Description Default Setting ECU
Foot/DEF Automatic Blow Up Function Function to increase the blower level automatically when the defroster is on ON $00:OFF,$01:ON Air conditioning amplifier assembly
Foot/DEF Auto Mode Function to change the air outlet mode to foot/defroster automatically when AUTO mode is on ON $00:OFF,$01:ON Air conditioning amplifier assembly
Efficient Ventilation Mode Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly ON $00:OFF,$01:ON Air conditioning amplifier assembly
ECO Mode Control Function to disable the operation of the ECO switch assembly (air conditioning control assembly) when set to OFF*1 ON $00:OFF,$01:ON Air conditioning amplifier assembly
Fan Speed Increment Control Function to set the speed to reach the target blower fan speed when AUTO mode is on Normal $01:Short,$00:Normal,$02:Long Air conditioning amplifier assembly
Outside Air Mode Auto Switch Function Function to automatically change the air inlet to FRESH mode when the ignition switch is off for 60 seconds ON $00:OFF,$01:ON Air conditioning amplifier assembly
Noise and Vibration Reduction Function to change the speed of the compressor when set to ON OFF $00:OFF,$01:ON Air conditioning amplifier assembly
Set Temperature Shift Function to perform control with the shifted temperature versus the displayed temperature Normal $05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C Air conditioning amplifier assembly
Refrigerant Shortage Check Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON ON $00:OFF,$01:ON Air conditioning amplifier assembly
50006 11

*1: Make sure to disable ECO mode control before setting this customize setting to ON.