MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU).
The cause of this malfunction may be the following:
Motor generator control ECU (MG ECU) malfunction
The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU) and stores this DTC when it detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation | The motor generator control ECU (MG ECU) value received by the hybrid vehicle control ECU exceeds the threshold for a certain period of time.
(1 trip detection logic) |
·
Hybrid motor control inverter assembly ·
Fusible link block assembly (IGCT-MAIN) ·
IGCT relay |
Comes on | Master Warning: Comes on | Hybrid Control | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 2 minutes or more.
If the vehicle has returned to normal, it can be driven after turning the ignition switch to ON (READY).
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Check the connection of the negative (-) and positive (+) auxiliary battery terminals.
The terminals are connected securely and there is no contact problem.
If performing a reproduction test, turn the ignition switch to ON and shake the wire harnesses vertically and horizontally before checking for DTCs.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the installation condition of the ground wires PA.
The ground wires PA are securely installed.
If performing a reproduction test, turn the ignition switch to ON and shake the wire harnesses vertically and horizontally before checking for DTCs.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the cable from the positive (+) auxiliary battery terminal.
Check the fusible link block assembly connector O90 for improper installation.
The fusible link block assembly is installed securely and there is no contact problem.
Procedure1
| *1 | Fusible Link Block Assembly |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O90)Location & Routingewd_type=routing;type=c;code=O90 Click Connector(O90)Body>Floor Wire>Fusible Link Block Assemblyewd_type=component;type=c;code=O90;pinno=1 |
||
| O90-1 (IGCT-MAIN) - A-1 (Positive (+) auxiliary battery terminal) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the cable from the positive (+) auxiliary battery terminal.
Reconnect the cable from the negative (-) auxiliary battery terminal.
OK
NG
Pre-procedure1
Check the IGCT relay for improper installation.
The relay is installed securely.
If performing a reproduction test, turn the ignition switch to ON and gently vibrate the IGCT relay with a finger before checking for DTCs.
| *1 | No. 5 Relay Block Assembly |
| *2 | IGCT relay |
Remove the IGCT relay from the No. 5 relay block assembly.
Procedure1
| *1 | IGCT relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the IGCT relay.
OK
NG
Pre-procedure1
None.
Procedure1
Check for DTCs.
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| P0A1B94 and other DTCs are output | A |
| Only P0A1B94 is output | B |
| None of the above conditions are met | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Turn the ignition switch to ON and wait for 2 minutes or more.
Turn the ignition switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A1B94 and other DTCs are output | A |
| Only P0A1B94 is output | B |
| DTCs are not output | C |
Post-procedure1
Turn the ignition switch off.
A
B
C