The hybrid vehicle control ECU stores a DTC when there is no auxiliary battery voltage to the IGR terminal even though there is auxiliary battery voltage to the IGP terminal.
When the ignition switch is turned to ON, the auxiliary battery power source is supplied to the IGP and IGR terminals of the hybrid vehicle control ECU. When the ignition switch is off, the auxiliary battery power source is cut off.
When the ignition switch is turned off during driving, the auxiliary battery power source supplied to the IGP terminal is cut off. However, the auxiliary battery power source supplied to the IGR terminal is supplied until the vehicle is stopped*1 or until the vehicle is stopped and the ignition switch is turned off*2.
*1: w/o Entry and Start System
*2: w/ Entry and Start System
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P253314 | Ignition Switch On/Start Position Circuit Low Circuit Short to Ground or Open | Short to ground or open in IGR terminal circuit.
(2 trip detection logic) |
·
Power distribution box assembly ·
Wire harness or connector ·
Hybrid vehicle control ECU |
Does not come on | Master Warning: Does not come on | Hybrid Control | A |
After repair has been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch ON (READY) and wait for 1 minute or more.
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before replacing the certification ECU (smart key ECU assembly), refer to Service Bulletin.
Read the Data List.
| Tester Display |
|---|
| IGR |
| GTS Display | Switch Condition | Specified Condition |
|---|---|---|
| IGR | Ignition switch ON | ON |
| Result | Proceed to |
|---|---|
| The value of IGR is ON | A |
| None of the above conditions are met | B |
A
B
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68,H44)Location & Routingewd_type=routing;type=c,c;code=A68,H44 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=33 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=15 |
||
| A68-33 (IGR) - H44-15 (E1) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the A68 hybrid vehicle control ECU connector.
Disconnect the 4D power distribution box assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68)Location & Routingewd_type=routing;type=c;code=A68 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=33 |
||
| 4D-22 - A68-33 (IGR) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A68)Location & Routingewd_type=routing;type=c;code=A68 Click Connector(A68)Instrument Panel>Engine Room Main Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=A68;pinno=33 |
||
| 4D-22 or A68-33 (IGR) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the 4B and 4C power distribution box assembly connectors.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4B-36 - Body ground | Always | Below 1 Ω |
| 4C-41 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG