HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P06B01C  Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range  P06D61C  Generator Control Module Offset Power Circuit Voltage Out of Range  P0A1A47  Generator Control Module Watchdog / Safety μC Failure  P0A1A49  Generator Control Module Internal Electronic Failure  P1C2A1C  Generator A/D Converter Circuit Circuit Voltage Out of Range  P1C2A49  Generator A/D Converter Circuit Internal Electronic Failure  P1C2A71  Generator A/D Converter Circuit Actuator Stuck  P1C2B1C  Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range  P1C2B49  Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure  P1C2B71  Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck  P1C601F  Generator Control Module Position Sensor REF Power Source Circuit Intermittent  P1C621F  Generator Control Module Offset Power Circuit Intermittent  P313383  Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect  P313386  Communication Error from Generator to Drive Motor "A" Signal Invalid  P313387  Communication Error from Generator to Drive Motor "A" Missing Message  P313483  Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect  P313486  Communication Error from Drive Motor "A" to Generator Signal Invalid  P313487  Communication Error from Drive Motor "A" to Generator Missing Message  


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the hybrid motor control inverter assembly, monitors its internal operation and will store DTCs if it detects a malfunction. If any of the following DTCs are output, replace the hybrid motor control inverter assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P0A1A47 Generator Control Module Watchdog / Safety μC Failure Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P0A1A49 Generator Control Module Internal Electronic Failure Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2A71 Generator A/D Converter Circuit Actuator Stuck Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C2B71 Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P1C601F Generator Control Module Position Sensor REF Power Source Circuit Intermittent Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
Hybrid motor control inverter assembly Does not come on Master Warning:
Does not come on
Motor Generator A
P1C621F Generator Control Module Offset Power Circuit Intermittent Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
Hybrid motor control inverter assembly Does not come on Master Warning:
Does not come on
Motor Generator A
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P313387 Communication Error from Generator to Drive Motor "A" Missing Message Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A
P313487 Communication Error from Drive Motor "A" to Generator Missing Message Motor generator control ECU internal malfunction
(1 trip detection logic)
Hybrid motor control inverter assembly Comes on Master Warning:
Comes on
Motor Generator A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 15 seconds or more.

4.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




PROCEDURE

1.REPLACE HYBRID MOTOR CONTROL INVERTER ASSEMBLY

NEXT

COMPLETED