MALFUNCTION DESCRIPTION
These DTCs indicate that the boost converter temperature sensor (upper) value is abnormal. The cause of this malfunction may be one of the following:
Hybrid motor control inverter assembly internal circuit malfunction
Coolant circulation abnormal (frozen or leaking, etc.)
The connectors are not connected properly
The motor generator control ECU, which is built into in the hybrid motor control inverter assembly, detects the temperature of the boost converter using the temperature sensor built into the boost converter. If necessary, the motor generator control ECU will limit inverter output to help prevent boost converter overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0C381C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range | The actual boost converter temperature (upper) high and the difference between the estimated boost converter temperature (upper) and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the boost converter temperature (upper) sensor value differs from the values of other sensors
(1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Hybrid motor control inverter assembly ·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Inverter water pump assembly |
Comes on | Master Warning:
Comes on |
Motor Generator | A |
| DTC No. | Data List |
|---|---|
| P0C381C | ·
Boosting Converter Temperature (Upper) ·
Inverter Coolant Temperature |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY).
Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25°C (77°F) or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
Refer to the wiring diagram for the Cooling System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0C381C for Motor generator control system is output | A |
| P0C381C and DTCs other than the DTCs in the table below are output | B |
| P0C381C and Hybrid control system DTCs in the table below are output | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Sensor and actuator circuit malfunction | Hybrid control system | P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | ||
| System malfunction | Hybrid control system | P0A9300 | Inverter "A" Cooling System Performance |
| System | Relevant DTC | |
|---|---|---|
| Motor generator control system | P0C381C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
P0C381C may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| NEXT |
NEXT