| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | Short to GND detected in reactor current sensor circuit
(1 trip detection logic) |
Hybrid motor control inverter assembly | Comes on | Master Warning:
Comes on |
Motor Generator | A |
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | Open or short to +B detected in reactor current sensor circuit
(1 trip detection logic) |
Hybrid motor control inverter assembly | Comes on | Master Warning:
Comes on |
Motor Generator | A |
| P0E511F | DC/DC Converter Current Sensor Circuit Intermittent | Short to ground, open or short to +B detected in reactor current sensor circuit when DTC P0C7917, P0E5717, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Hybrid motor control inverter assembly | Does not come on | Master Warning:
Does not come on |
Motor Generator | A |
| DTC No. | Data List |
|---|---|
| P0E5111
P0E5115 P0E511F |
Inverter Input Current |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
| Proceed to |
|---|
| NEXT |
NEXT