If the motor generator control ECU, which is built into in the hybrid motor control inverter assembly, is reset due to a problem with the power source in the inverter, the motor generator control ECU will stored this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A1B1F | Generator Control Module Circuit Intermittent | Error in reset signal from the inverter assembly power source IC:
If internal power source voltage drops below the normal CPU operating voltage or the ROM/RAM is malfunctioning, the power source IC resets the MG ECU and stores this DTC. (1 trip detection logic) |
·
Wire harness or connector ·
Hybrid motor control inverter assembly ·
Auxiliary battery terminal |
Comes on | Master Warning:
Comes on |
Motor Generator | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 15 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A1B1F for Motor generator control system is output | A |
| P0A1B1F and Motor generator control system DTCs in the table below are output | B |
| P0A1B1F and Hybrid control system DTCs in the table below are output | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
| Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message | ||
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Check the connection of the auxiliary battery terminal.
The terminal is connected securely and there is no contact problem.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 hybrid motor control inverter assembly connector.
Remove the IGCT relay from the No. 5 relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Relay Block Assembly | *2 | IGCT Relay Holder |
| *a | Front view of wire harness connector
(to Hybrid Motor Control Inverter Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A56)Location & Routingewd_type=routing;type=c;code=A56 Click Connector(A56)Engine Compartment>Engine Room Main Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=A56;pinno=6,5,24,23 |
||
| A56-6 (+B) - 5 (IGCT relay holder) | Ignition switch off | Below 1 Ω |
| A56-5 (+B2) - 5 (IGCT relay holder) | Ignition switch off | Below 1 Ω |
| A56-24 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A56-23 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the IGCT relay.
Reconnect the A56 hybrid motor control inverter assembly connector.
OK
NG
Check for intermittent problems.
Check the connection and terminal contact pressure of the connectors and wire harnesses between the auxiliary battery and the hybrid motor control inverter assembly.
There are no abnormalities in the wire harnesses and connectors.
| Proceed to |
|---|
| OK |
| NG |
OK
NG