Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0441185 HYBRID BATTERY SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  TERMINALS OF ECU  


A458599C01
1.063,5.75 1.479,6.031 0.417,0.281 3.385,5.75 3.802,6.031 0.417,0.281 5.719,5.75 6.135,6.031 0.417,0.281 1.177,5.813 1.635,6.01 0.458,0.198 10 false z12 3.479,5.813 3.938,6.01 0.458,0.198 10 false z13 5.802,5.813 6.26,6.01 0.458,0.198 10 false z15 0.104,0.073 0.417,0.271 0.313,0.198 10 false *1
*1 Battery ECU assembly - -


Terminal No.
(Symbols)
Terminal Description Condition Specified Condition
z12-12 (AM) - z12-34 (GND) Constant power source Always 11 to 14 V
z12-24 (IGCT) - z12-34 (GND) Power source Ignition switch ON 11 to 15.5 V
z12-5 (TC0) - z12-6 (GC0) Intake air temperature sensor Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-19 (IB0) - z12-7 (GIB) Battery current sensor 0 Ignition switch ON Approximately 2.57 V
z12-8 (IB1) - z12-7 (GIB) Battery current sensor 1 Ignition switch ON Approximately 2.43 V
z12-31 (VIB) - z12-7 (GIB) Power source for battery current sensor Ignition switch ON 4.5 to 5.5 V
z12-22 (FP0) - z12-34 (GND) Battery cooling blower monitor signal Cooling fans operating Pulse generation
(Waveform 1)
Cooling fans not operating 0 Hz
z12-23 (SI0) - z12-34 (GND) Battery cooling blower operation signal Cooling fans operating Pulse generation
(Waveform 2)
Cooling fans not operating 4.5 to 5.5 V
z12-25 (TB0) - z12-26 (GB0) Battery temperature sensor 0 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-27 (TB1) - z12-28 (GB1) Battery temperature sensor 1 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-16 (TB2) - z12-15 (GB2) Battery temperature sensor 2 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-3 (TB3) - z12-4 (GB3) Battery temperature sensor 3 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-29 (TB4) - z12-30 (GB4) Battery temperature sensor 4 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-18 (TB5) - z12-17 (GB5) Battery temperature sensor 5 Ignition switch ON
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V (90°C)
z12-32 (CA2L) - z12-34 (GND) CAN communication line Ignition switch ON Pulse generation
(Waveform 3)
z12-33 (CA2H) - z12-34 (GND) CAN communication line Ignition switch ON Pulse generation
(Waveform 3)
z12-34 (GND) - Body ground Ground Always Below 1 Ω
z12-35 (CA1L) - z12-34 (GND) CAN communication line Ignition switch ON Pulse generation
(Waveform 4)
z12-36 (CA1H) - z12-34 (GND) CAN communication line Ignition switch ON Pulse generation
(Waveform 4)
z13-28 (GA1) - z13-5 (VA25) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-5 (VA25) - z13-17 (VA26) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-17 (VA26) - z13-29 (VA27) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-29 (VA27) - z13-6 (VA28) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-6 (VA28) - z13-18 (VA29) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-18 (VA29) - z13-30 (VA30) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-30 (VA30) - z13-7 (VA31) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-7 (VA31) - z13-19 (VA32) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-19 (VA32) - z13-31 (VA33) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-31 (VA33) - z13-8 (VA34) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-8 (VA34) - z13-20 (VA35) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-20 (VA35) - z13-32 (VA36) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-32 (VA36) - z13-9 (VA37) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-9 (VA37) - z13-21 (VA38) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-21 (VA38) - z13-33 (VA39) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-33 (VA39) - z13-10 (VA40) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-10 (VA40) - z13-22 (VA41) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-22 (VA41) - z13-34 (VA42) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-34 (VA42) - z13-11 (VA43) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-11 (VA43) - z13-23 (VA44) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-23 (VA44) - z13-35 (VA45) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-35 (VA45) - z13-12 (VA46) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-12 (VA46) - z13-24 (VA47) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-24 (VA47) - z13-36 (VA48) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-28 (GA0) - z15-5 (VA1) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-5 (VA1) - z15-17 (VA2) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-17 (VA2) - z15-29 (VA3) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-29 (VA3) - z15-6 (VA4) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-6 (VA4) - z15-18 (VA5) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-18 (VA5) - z15-30 (VA6) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-30 (VA6) - z15-7 (VA7) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-7 (VA7) - z15-19 (VA8) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-19 (VA8) - z15-31 (VA9) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-31 (VA9) - z15-8 (VA10) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-8 (VA10) - z15-20 (VA11) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-20 (VA11) - z15-32 (VA12) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-32 (VA12) - z15-9 (VA13) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-9 (VA13) - z15-21 (VA14) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-21 (VA14) - z15-33 (VA15) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-33 (VA15) - z15-10 (VA16) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-10 (VA16) - z15-22 (VA17) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-22 (VA17) - z15-34 (VA18) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-34 (VA18) - z15-11 (VA19) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-11 (VA19) - z15-23 (VA20) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-23 (VA20) - z15-35 (VA21) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-35 (VA21) - z15-12 (VA22) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-12 (VA22) - z15-24 (VA23) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-24 (VA23) - z15-36 (VA24) Hybrid Battery Cell Voltage Always 1.9 to 4.1 V

Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
A366609N02
2.969,1 3.385,1.448 0.417,0.448 10 false GND

Waveform 1

Item Content
Terminal z12-22 (FP0) - z12-34 (GND)
Equipment Setting 2 V/DIV., 2 ms/DIV.
Condition Battery cooling blower assembly operating (Active Test of cooling fan being performed)

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.



b.
C257882N01
2.99,1.052 3.302,1.292 0.313,0.24 10 GND

Waveform 2

Item Content
Terminal z12-23 (SI0) - z12-34 (GND)
Equipment Setting 10 V/DIV., 1 ms/DIV.
Condition Battery cooling blower assembly operating (Active Test of cooling fan being performed)

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.



c.
A298838N01
3.01,1.229 3.375,1.469 0.365,0.24 10 GND 3.031,1.604 3.396,1.844 0.365,0.24 10 GND 0.302,0.865 0.667,1.104 0.365,0.24 10 CH1 0.323,1.427 0.688,1.667 0.365,0.24 10 CH2

Waveform 3

Item Content
Terminal CH1: z12-33 (CA2H) - z12-34 (GND)
CH2: z12-32 (CA2L) - z12-34 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Ignition switch ON

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



d.
A298838N01
3.01,1.229 3.375,1.469 0.365,0.24 10 GND 3.031,1.604 3.396,1.844 0.365,0.24 10 GND 0.302,0.865 0.667,1.104 0.365,0.24 10 CH1 0.323,1.427 0.688,1.667 0.365,0.24 10 CH2

Waveform 4

Item Content
Terminal CH1: z12-36 (CA1H) - z12-34 (GND)
CH2: z12-35 (CA1L) - z12-34 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Ignition switch ON

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).