G3850
1.INSPECT NO.1 TRACTION BATTERY DEVICE BOX ASSEMBLY (for 2WD)
Inspect SMRB:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a1,z10)Location & Routingewd_type=routing;type=c,c;code=a1,z10 Click Connector(a1)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a1;pinno=1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 |
||
| a1-1 (CBI) - z10-1 (+) | Auxiliary battery voltage not applied between terminals O70-1 (SMRB) and O70-3 (GND) | 10 kΩ or higher |
| a1-1 (CBI) - z10-1 (+) | Auxiliary battery voltage applied between terminals O70-1 (SMRB) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,3 |
||
| O70-1 (SMRB) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.
Inspect SMRG:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a2,z9)Location & Routingewd_type=routing;type=c,c;code=a2,z9 Click Connector(a2)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a2;pinno=1 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 |
||
| a2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage not applied between terminals O70-4 (SMRG) and O70-3 (GND) | 10 kΩ or higher |
| a2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage applied between terminals O70-4 (SMRG) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=4,3 |
||
| O70-4 (SMRG) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.
Inspect SMRP:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a2,z9)Location & Routingewd_type=routing;type=c,c;code=a2,z9 Click Connector(a2)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a2;pinno=1 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 |
||
| a2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage not applied between terminals O70-2 (SMRP) and O70-3 (GND) | 10 kΩ or higher |
| a2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage applied between terminals O70-2 (SMRP) and O70-3 (GND) | 24.3 to 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=2,3 |
||
| O70-2 (SMRP) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.
G3850
2.INSPECT NO.1 TRACTION BATTERY DEVICE BOX ASSEMBLY (for AWD)
Inspect SMRB:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c1,z10)Location & Routingewd_type=routing;type=c,c;code=c1,z10 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 |
||
| c1-1 (CBI) - z10-1 (+) | Auxiliary battery voltage not applied between terminals O70-1 (SMRB) and O70-3 (GND) | 10 kΩ or higher |
| c1-1 (CBI) - z10-1 (+) | Auxiliary battery voltage applied between terminals O70-1 (SMRB) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,3 |
||
| O70-1 (SMRB) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.
Inspect SMRG:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c2,z9)Location & Routingewd_type=routing;type=c,c;code=c2,z9 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 |
||
| c2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage not applied between terminals O70-4 (SMRG) and O70-3 (GND) | 10 kΩ or higher |
| c2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage applied between terminals O70-4 (SMRG) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=4,3 |
||
| O70-4 (SMRG) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.
Inspect SMRP:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c2,z9)Location & Routingewd_type=routing;type=c,c;code=c2,z9 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 |
||
| c2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage not applied between terminals O70-2 (SMRP) and O70-3 (GND) | 10 kΩ or higher |
| c2-1 (CEI) - z9-1 (-) | Auxiliary battery voltage applied between terminals O70-2 (SMRP) and O70-3 (GND) | 24.3 to 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=2,3 |
||
| O70-2 (SMRP) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
If the result is not as specified, replace the No. 1 traction battery device box assembly.