| Item | Specified Condition |
|---|---|
| Standard Value (for Brand-new Cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum Standard Value (for Used Cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
| IGCT-MAIN relay
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
| SMRB
Resistance |
a1-1 (CBI) - z10-1 (+) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-1 (SMRB) and M37-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals M37-1 (SMRB) and M37-3 (GND) |
||
| O70-1 (SMRB) - O70-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG
Resistance |
a2-1 (CEI) - z9-1 (-) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-4 (SMRG) and M37-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals M37-4 (SMRG) and M37-3 (GND) |
||
| O70-4 (SMRG) - O70-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRP
Resistance |
a2-1 (CEI) - z9-1 (-) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-2 (SMRP) and M37-3 (GND) |
| 24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals M37-2 (SMRP) and M37-3 (GND) |
||
| O70-2 (SMRP) - O70-3 (GND) | 140 to 290 Ω at -40 to 80°C (-40 to 176°F) |
| Pattern Select Switch Assembly
Resistance |
H18-6(S) - H18-5(E) | Below 50 Ω
(EV mode switch (pattern select switch assembly) being pushed and held) |
| 10 kΩ or higher
(EV mode switch (pattern select switch assembly) not pushed) |
||
| H18-8(DRV) - H18-5(E) | Below 50 Ω
(DRIVE mode switch (pattern select switch assembly) being pushed and held) |
|
| 10 kΩ or higher
(DRIVE mode switch (pattern select switch assembly) not pushed) |
||
| Auxiliary Battery positive (+) - H18-4 (ILL+)
Auxiliary Battery negative (-) - H18-1 (ILL-) |
Illuminates |
| Service plug grip | - | Below 1 Ω |
| Hybrid Battery Terminal Block | - | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A - C | Always | Below 1 Ω |
| B - D | Below 1 Ω |