Home › General › SPECIFICATIONS › M15A-FXE STARTING
RM3700E _V1 General _093022 SPECIFICATIONS _0442320 M15A-FXE STARTING F

SPECIFICATIONS  M15A-FXE STARTING  SERVICE DATA  


Ignition or Starter Switch Assembly
Item Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
H54-6 (ACC) - H54-7 (AM1) ACC Below 1 Ω
H54-6 (ACC) - H54-7 (AM1) - H54-8(IG1) ON Below 1 Ω
H54-1 (AM2) - H54-2 (IG2)
H54-5 (ST1) - H54-7 (AM1) - H54-8 (IG1) START Below 1 Ω
H54-1 (AM2) - H54-2 (IG2) - H54-4 (ST2)

Power Switch
Tester Connection Condition Specified Condition

Click Location & Routing(H69)Location & Routing

Click Connector(H69)Instrument Panel>Instrument Panel Wire / Speaker Wire>Power Switch

H69-12(SS1) - H69-3(GND)
H69-6(SS2) - H69-3(GND)
H69-11(SS3) - H69-3(GND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω
H69-5(SWIL) - H69-3(GND) H69-5(SWIL) - Auxiliary battery positive (+)
H69-3(GND) - Auxiliary battery negative (-)
Illuminates