RM3700E
_V1
General
_093022
SPECIFICATIONS
_0442319
M15A-FKS STARTING
F
SPECIFICATIONS M15A-FKS STARTING SERVICE DATA
Starter Assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| Battery positive (+) terminal - Terminal 30 - Terminal 50
|
11.5 V
|
Below 90 A
|
Magnet start switch assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| Terminal 50 - Magnet starter switch assembly body
|
Always
|
Below 2 Ω
|
Starter Armature Assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| Segment - Segment
|
Always
|
Below 1 Ω
|
| Segment - Starter armature core
|
10 kΩ or higher
|
| Commutator runout
|
Maximum runout
|
0.05 mm (0.00197 in.)
|
| Commutator diameter
|
Standard diameter
|
25.0 mm (0.984 in.)
|
| Minimum diameter
|
24.0 mm (0.945 in.)
|
| Undercut depth
|
Standard undercut depth
|
0.7 mm (0.0276 in.)
|
| Minimum undercut depth
|
0.2 mm (0.00787 in.)
|
Starter Brush Holder Assembly
| Brush length
|
Standard length
|
11.6 mm (0.457 in.)
|
| Minimum length
|
7.6 mm (0.299 in.)
|
ST No. 1 Relay
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage not applied to terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied to terminals 1 and 2
|
Below 1 Ω
|