DATA LIST
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model, operating under identical conditions in order to reach an overall judgment by comparing all of the items in the Data List.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Rear Motor Generator / Data List.
Check the results by referring to the following table.
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
Using a custom list makes it possible to easily select smaller groups of related Data List items.
The following custom lists are available:
All Data
Inverter
Resolver
DC/DC Converter
Resolver Learning
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Engine Speed | Engine speed | - | ·
Engine stopped: 0 rpm ·
While engine running at a constant speed: No significant fluctuation |
- |
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | ·
Vehicle stopped: 0 km/h (0 mph) ·
While driving at a constant speed: No significant fluctuation |
- |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec | Elapsed time after starting engine | Elapsed time from initial engine start until the ignition switch is turned off. |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Warmup Cycle Cleared DTC | The number of times the engine is warmed up after clearing DTCs | Min.: 0, Max.: 255 | MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine:
Increases once |
- |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Battery Voltage | Auxiliary battery voltage
(Battery voltage sensor power source voltage) |
Min.: 0.00 V, Max.: 16.00 V | 11.00 to 15.00 V | When ignition switch ON (READY): approx. 12.5 to 15.0 V. When ignition switch ON: same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the ignition switch is ON (READY), the hybrid vehicle control ECU stores hybrid motor control inverter assembly DTCs. If the voltage becomes 9.5 V or less, the ignition switch will not be able to be turned to ON (READY). |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Ignition switch ON:
Same as ambient air temperature |
- |
| Time after DTC Cleared | Time after DTCs cleared | Min.: 0 min, Max.: 65535 min | - | - |
| Hybrid/EV Battery System Voltage | HV battery voltage | Min.: 0 V, Max.: 510 V | Ignition switch ON (READY):
150 to 300 V |
- |
| Hybrid/EV Battery System Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A | Ignition switch ON:
-3.1 to 3.1 A |
- |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | While driving:
Varies depending on vehicle speed |
Motor (MG2) speed changes in proportion to vehicle speed.
Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed. |
| Motor Torque | Motor (MG2) torque value | Min.: -4096 Nm, Max.: 4095.875 Nm | While driving:
Varies depending on vehicle operating conditions |
- |
| Motor Control Mode | Motor control mode | Min.: 0, Max.: 65535 | - | - |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | During charge or discharge:
Varies depending on vehicle operating conditions |
Generator (MG1) speed is set to obtain requested target engine speed |
| Generator Torque | Generator (MG1) torque value | Min.: -4096 Nm, Max.: 4095.875 Nm | During charge or discharge:
Varies depending on vehicle operating conditions |
- |
| Generator Control Mode | Generator control mode | Min.: 0, Max.: 65535 | - | - |
| VL Voltage | High voltage before it is boosted | Min.: 0.0 V, Max.: 6553.5 V | Ignition switch ON (READY):
Practically the same as the HV battery voltage |
- |
| VH Voltage | High voltage after it is boosted | Min.: 0.0 V, Max.: 6553.5 V | Engine revving up with shift lever in P:
After boosted voltage to below 580 V |
- |
| Boosting Converter PWM Duty | Boost converter PWM duty | Min.: 0 %, Max.: 100 % | - | - |
| Boosting Converter Control Mode | Boost converter control mode | Min.: 0, Max.: 255 | - | - |
| Short Wave Highest Value | Waveform voltage in abnormal insulation detection circuit in battery voltage sensor | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Fail Safe Mode | Fail safe mode | Min.: -128, Max.: 127 | - | - |
| Accelerator Position | Accelerator position | Min.: 0 %, Max.: 100.0 % | Accelerator pedal depressed:
Changes with accelerator pedal pressure |
- |
| WIN Control Limit Power | Power flowing to HV battery (Charging)
(detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW | -26.85 kW or more | - |
| WOUT Control Limit Power | Power flowing from HV battery (Discharging)
(detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW | 22.50 kW or less | - |
| VLR Voltage | Voltage before boosting input to rear motor inverter | Min.: 0.0 V, Max.: 6553.5 V | Ignition switch ON (READY):
Practically the same as the HV battery voltage |
- |
| Rear Motor Resolver After Offset | Rear Motor resolver after offset | Min.: 0.000 deg, Max.: 358.593 deg | - | - |
| Rear Motor V Current 1ch (Lower Resolution) | Rear Motor V phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor V Current 2ch (Lower Resolution) | Rear Motor V phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor W Current 1ch (Lower Resolution) | Rear Motor W phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor W Current 2ch (Lower Resolution) | Rear Motor W phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor Revolution | Rear Motor (MGR) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | While driving:
Varies depending on vehicle speed |
- |
| Rear Motor Torque | Rear Motor (MGR) torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm | While driving:
Varies depending on vehicle speed |
- |
| Rear Motor Control Mode | Rear Motor control mode | Min.: 0, Max.: 65535 | - | - |
| Rear Motor Carrier Frequency | Rear Motor carrier frequency | Min.: 0, Max.: 255 | - | - |
| Rear Motor Inverter Shut Down Signal | Rear Motor inverter shutdown signal | Min.: 0, Max.: 255 | - | - |
| Rear Motor ECU Power Supply (For 31V) | Rear Motor generator control ECU power supply (for 31V) | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Rear Motor ECU Power Supply (For AD0) | Rear Motor generator control ECU power supply (for AD0) | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Rear Motor ECU Power Supply (For 2.5V) | Rear Motor generator control ECU power supply (for 2.5V) | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Rear Motor Inverter Temperature | Rear Motor inverter temperature | Min.: 0°C (32°F), Max.: 255°C (491°F) | ·
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) ·
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
- |
| Rear Motor Temperature | Rear Motor (MGR) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | ·
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) ·
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
- |
| Rear Motor V Current AD Value 1ch(Lower Resolution) | Rear Motor V phase current AD value (Lower resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor V Current AD Value 2ch(Lower Resolution) | Rear Motor V phase current AD value (Lower resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor W Current AD Value 1ch(Lower Resolution) | Rear Motor W phase current AD value (Lower resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor W Current AD Value 2ch(Lower Resolution) | Rear Motor W phase current AD value (Lower resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor V Current AD Value 1ch(Higher Resolution) | Rear Motor V phase current AD value (Higher resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor W Current AD Value 1ch(Higher Resolution) | Rear Motor W phase current AD value (Higher resolution) | Min.: 0.00 V, Max.: 4.99 V | - | - |
| VLR Voltage AD Value | AD value of voltage before boosting input to rear motor inverter | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Rear Motor Inverter Temperature Duty | Rear Motor inverter temperature duty (CPU input data) | Min.: 0.0 %, Max.: 6553.5 % | - | - |
| Rear Motor Base Temperature | Rear Motor (MGR) Base temperature | Min.: -50.0000°C (-58.0000°F), Max.: 205.9960°C (402.7928°F) | - | - |
| Rear Motor Base Temperature AD Value | Rear Motor (MGR) Base temperature AD value | Min.: 0.00 V, Max.: 4.99 V | - | - |
| Emergency Shutdown Signal | Inverter emergency shutdown | ON or OFF | ·
Inverter emergency shutdown: ON ·
Normal: OFF |
- |
| Ready ON Status | State of system (READY) | ON or OFF | Ignition switch ON (READY):
ON |
- |
| SMR Status | System main relay status | ON or OFF | Ignition switch ON (READY):
ON |
- |
| Generator Inverter High Current(GFINV) | Generator (MG1) inverter high current | ON or OFF | Normal:
OFF |
- |
| Generator Inverter Shut Down Status | Generator (MG1) inverter shutdown status | ON or OFF | ·
Generator inverter shutdown: ON ·
Normal: OFF |
- |
| Motor Inverter High Current(MFINV) | Motor inverter high current | ON or OFF | Normal:
OFF |
- |
| Motor Inverter Shut Down Status | Motor inverter shutdown | ON or OFF | ·
Motor inverter shutdown: ON ·
Normal: OFF |
- |
| Boosting Converter Input High Voltage | Boost converter input high voltage | ON or OFF | Normal:
OFF |
- |
| Boosting Converter Input High Current(CFINV) | Boost converter input high current | ON or OFF | Normal:
OFF |
- |
| Boosting Converter Shut Down Status | Boost converter shutdown | ON or OFF | ·
Boost converter shutdown: ON ·
Normal: OFF |
- |
| Rear Inverter Input High Voltage | Rear Inverter input high voltage | ON or OFF | Normal:
OFF |
- |
| Rear Inverter Input High Current (RFINV) | Rear Inverter input high current | ON or OFF | Normal:
OFF |
- |
| Rear Inverter Shut Down Status | Rear inverter shutdown | ON or OFF | ·
Rear Motor inverter shutdown: ON ·
Normal: OFF |
- |
| Rear Inverter Cooling Fan | Rear inverter cooling fan operating condition | Stop or Start | ·
When rear inverter cooling fan is commanded to stop operating (fan is stopped): Stop ·
When rear inverter cooling fan is commanded to operate (fan is spinning): Start |
- |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile | - | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).
After performing the Active Test, turn the ignition switch off before proceeding to the next step.
According to the display on the GTS perform the appropriate Active Test.
| Tester Display | Measurement Item | Restrict Condition | Diagnostic Note |
|---|---|---|---|
| Rear Inverter Cooling Fan | Rear inverter cooling fan operation | Ignition switch ON | Rear inverter cooling fan can be stopped/started |