This circuit provides power to operate the blind spot monitor sensor.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the T6 blind spot monitor sensor LH (B) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(T6)Location & Routingewd_type=routing;type=c;code=T6 Click Connector(T6)Body>No. 8 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=T6;pinno=5 |
||
| T6-5 (BLB) - Body ground | Ignition switch ON | 11 to 14 V |
| T6-5 (BLB) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the T6 blind spot monitor sensor LH (B) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(T6)Location & Routingewd_type=routing;type=c;code=T6 Click Connector(T6)Body>No. 8 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=T6;pinno=10 |
||
| T6-10 (BLGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the S6 blind spot monitor sensor RH (A) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(S6)Location & Routingewd_type=routing;type=c;code=S6 Click Connector(S6)Body>No. 7 Floor Wire>Blind Spot Monitor Sensor RHewd_type=component;type=c;code=S6;pinno=5 |
||
| S6-5 (BRB) - Body ground | Ignition switch ON | 11 to 14 V |
| S6-5 (BRB) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the S6 blind spot monitor sensor RH (A) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(S6)Location & Routingewd_type=routing;type=c;code=S6 Click Connector(S6)Body>No. 7 Floor Wire>Blind Spot Monitor Sensor RHewd_type=component;type=c;code=S6;pinno=10 |
||
| S6-10 (BRGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG