84988L
1.INSPECT VSC OFF SWITCH
| *a | Component without harness connected
(VSC OFF Switch) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H154)Location & Routingewd_type=routing;type=c;code=H154 Click Connector(H154)Instrument Panel>Instrument Panel Wire / Speaker Wire>VSC Off Switchewd_type=component;type=c;code=H154;pinno=2,5 |
||
| H154-2 (E) - H154-5 (+) | Switch pushed | Below 1 Ω |
| H154-2 (E) - H154-5 (+) | Switch not pushed | 10 kΩ or higher |
If the result is not as specified, replace the VSC OFF Switch.
| *a | Component without harness connected
(VSC OFF Switch) |
Check the illumination.
Apply auxiliary battery voltage to the VSC OFF Switch.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H154)Location & Routingewd_type=routing;type=c;code=H154 |
||
| H154-6 (ILL+) - H154-1 (ILL-) | H154-6 (ILL+) - Auxiliary battery positive (+)
H154-1 (ILL-) - Auxiliary battery negative (-) |
The VSC OFF Switch illumination illuminates. |
If the result is not as specified, replace the VSC OFF Switch.