Home › General › SPECIFICATIONS › ADVANCED PARK › from 2021.07
RM3700E _V1 General _093022 SPECIFICATIONS _0483192 ADVANCED PARK F

SPECIFICATIONS  ADVANCED PARK  SERVICE DATA  


ADVANCED PARK MAIN SWITCH
Tester Connection Condition Specified Condition

Click Location & Routing(H18)Location & Routing

Click Connector(H18)Instrument Panel>Instrument Panel Wire / Speaker Wire>Combination Switch Assembly

H18-3 (IG) - H18-2 (E) Advanced park main switch (combination switch assembly) is pushed Below 1 Ω
H18-3 (IG) - H18-2 (E) Advanced park main switch (combination switch assembly) is not pushed 10 kΩ or higher