Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model TMMF Made) › from 2021.07
RM3700E _54 Brake _093745 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0483473 ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for HV Model TMMF Made) C

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for HV Model TMMF Made)  C12B400  Electronic Brake Booster Motor "A"  C12B41C  Electronic Brake Booster Motor "A" Circuit Voltage Out of Range  C12B41E  Electronic Brake Booster Motor "A" Circuit Resistance Out of Range  C12B477  Electronic Brake Booster Motor "A" Commanded Position Not Reachable  C12B496  Electronic Brake Booster Motor "A" Component Internal Failure  C12B579  Electronic Brake Booster Motor "A" Mechanical Linkage Failure  


DESCRIPTION

The motor actuator is built into the brake booster with master cylinder assembly.

When the ABS, TRC, VSC, brake hold or brake assist is operating, the electric brake booster (brake booster with master cylinder assembly) turns the motor ON and operates the motor inside the electric brake booster (brake booster with master cylinder assembly).

DTC No. Detection Item DTC Detection Condition Trouble Area DTC Output from Priority
C12B400 Electronic Brake Booster Motor "A" Abnormality in motor actuator rotation is detected for 0.3 seconds or more. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A
C12B41C Electronic Brake Booster Motor "A" Circuit Voltage Out of Range Poor internal condition of motor actuator is detected. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A
C12B41E Electronic Brake Booster Motor "A" Circuit Resistance Out of Range Internal failure in motor actuator is detected for 0.12 seconds. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A
C12B477 Electronic Brake Booster Motor "A" Commanded Position Not Reachable Abnormality in motor actuator rotation is detected for 0.3 seconds or more. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A
C12B496 Electronic Brake Booster Motor "A" Component Internal Failure Detected that the motor actuator cannot be driven. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A
C12B579 Electronic Brake Booster Motor "A" Mechanical Linkage Failure Abnormality in motor actuator rotation is detected. Electric brake booster (brake booster with master cylinder assembly) Brake Booster A

CAUTION / NOTICE / HINT

NOTICE:

After replacing the electric brake booster (brake booster with master cylinder assembly), perform "Calibration" after performing "Reset Memory".

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model TMMF Made)>UTILITY


PROCEDURE

1.CHECK VEHICLE
a.

Check the vehicle specification.


Result:
Result Proceed to
for LHD A
for RHD B



A

2.REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY

B

3.REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY
2.REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY

NEXT

END

3.REPLACE BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY

NEXT

END