| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| C052C1C | ABS Pump Motor Control Circuit Voltage Out of Range | Any of the following is detected:
·
When the +BS terminal voltage is from 9.5 to 17.4 V with the motor relay and motor fail safe relay OFF, short in ground circuit continues for 2 seconds or more. ·
When the motor relay OFF and the motor fail-safe relay ON, an open or short in motor circuit continues for 4 seconds or more. |
Skid control ECU (brake actuator assembly) | Brake/EPB | A |
After replacing the skid control ECU (brake actuator assembly), perform "Calibration".
Procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Pre-procedure1
Disconnect the A94 skid control ECU (brake actuator assembly) connector.
Procedure2
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure3
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A94)Location & Routingewd_type=routing;type=c;code=A94 Click Connector(A94)Engine Compartment>Engine Room Main Wire>Brake Actuator Assemblyewd_type=component;type=c;code=A94;pinno=30 |
||
| A94-30 (GND2) - Body ground | 1 minute or more after disconnecting the cable from the negative (-) auxiliary battery terminal | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG