Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.07
RM3700E _57 Power Source / Network _092979 M15A-FKS BATTERY / CHARGING _0438220 CHARGING SYSTEM U

M15A-FKS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A425691E18
1.667,0.833 2.167,1.083 0.5,0.25 5.5,0.833 6,1.083 0.5,0.25 1.781,0.885 2.24,1.083 0.458,0.198 10 false D51 5.615,0.875 6.073,1.073 0.458,0.198 10 false A54

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Terminal Description Condition Specified Condition
A54-1 (BATT) - A54-10 (E1) Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
A54-10 (E1) - Body ground Ground Always Below 1 Ω
D51-63 (LIN) - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher