EMISSION CONTROL SYSTEM (for Hatchback) > DETAILS



FUNCTION OF MAIN COMPONENTS
  1. The main components of the exhaust emission control system are as follows:

    Component
    Function
    TWC
    Oxidizes CO and HC in the exhaust gas and deoxidizes NOx at the same time, to purify them into CO2, H2O and N2.
    Oxygen Sensor
    The signal of the air-fuel ratio sensor changes abruptly between lean and rich at the stoichiometric air fuel ratio. Located downstream of the catalytic converter.
    Air Fuel Ratio Sensor
    Is used to determine the concentration of oxygen remaining in the exhaust gas. Has a characteristic where its output is proportional to the engine air fuel ratio. Located upstream of the catalytic converter.
    ECM
    Controls the volume of fuel consumed based primarily on the signal from the air fuel ratio sensor, with minor corrections based on the signal from the oxygen sensor. This control optimizes the exhaust emissions.

  2. The main components of the evaporative emission control system are as follows:

    Component
    Function
    Canister
    Contains activated to absorb the fuel vapor that is created in the fuel tank assembly.
    Fresh Air Line
    Fresh air goes into the canister and the cleaned drain air goes out into the atmosphere.
    Canister Pump Module
    Vent Valve
    Opens and closes the fresh air line in accordance with signals from the ECM.
    Leak Detection Pump and Pump Motor
    Applies vacuum to the evaporative emission system in accordance with signals from the ECM.
    Canister Pressure Sensor
    Detects the pressure in the evaporative emission system and sends the signals to the ECM.
    Purge VSV
    Opens in accordance with the signals from the ECM when the system is purging, in order to send the fuel vapor that was absorbed by the canister into the intake manifold. In system monitoring mode, this valve controls the introduction of vacuum into the fuel tank assembly.
    Canister Filter
    Prevents dust and debris in the fresh air from entering the system.
    ECM
    Controls the canister pump module and the purge VSV in accordance with the signals from various sensors, in order to achieve a purge volume that suits the driving conditions. In addition, the ECM monitors the system for any leak and stores a DTC if a malfunction is found.


OPERATING CONDITION
  1. The following are the typical conditions necessary to enable an evaporative emission leak check:

    Typical Enabling Conditions
    1. 5 hours have elapsed after the engine has been turned off*.
    2. Altitude: Below 2400 m (8000 feet)
    3. Battery Voltage: 10.5 V or more
    4. Ignition Switch: off
    5. Engine Coolant Temperature: 4.4 to 35°C (40 to 95°F)
    6. Intake Air Temperature: 4.4 to 35°C (40 to 95°F)

    1. *: If engine coolant temperature does not drop below 35°C (95°F), this time is extended to 7 hours. Even after that, if the temperature is not less than 35°C (95°F), the time is extended to 9.5 hours.

      HINT:
      The canister pump module performs a fuel evaporative emission leak check. This check is done approximately 5 hours after the engine is turned off. Sound may be heard coming from underneath the luggage compartment for several minutes. This does not indicate a malfunction. Pinpoint pressure test procedure is adopted by pressurizing the fresh air line that runs from the canister pump module to the canister filter neck. For details, refer to the Repair Manual.


SYSTEM CONTROL


  1. Blowby Gas Ventilation System

    1. By introducing blowby gas that has a large amount of HC into the air intake side and burning it again, the system attempts to enhance the emission performance. Returning blowby gas volume is regulated to the appropriate amount corresponding to the engine operating conditions, reducing the engine oil quantity taken away and engine idling speeds.

    2. The ventilation valve sub-assembly passage returns the blowby gas into the area after the throttle valve in accordance with the intake manifold vacuum.



    3. When load is low, the passage from the cylinder head cover sub-assembly to the area before the throttle valve increases the air purification performance inside the crankcase by introducing fresh air, and when load is high, the passage circulates the blowby gas together with the ventilation valve sub-assembly side passage due to the intake manifold vacuum.


      W105000E01


      Text in Illustration 
      *1
      Ventilation Valve Sub-assembly
      -
      -
      *a
      When load is low
      *b
      When load is high
      V100135
      Blowby Gas
      V100136
      Fresh Air



  2. Purge Flow Control

    1. When the engine has reached a predetermined state [closed loop, engine coolant temperature above 70°C (158°F), etc.], stored fuel vapor is purged from the canister whenever the purge VSV is opened by the ECM.



    2. The ECM will change the duty ratio cycle of the purge VSV, thus controlling purge flow volume. Purge flow volume is determined by intake manifold pressure and the duty ratio cycle of the purge VSV. Atmospheric pressure is allowed into the canister to ensure that purge flow is constantly maintained whenever purge vacuum is applied to the canister.


      W105046E01



  3. Onboard Refueling Vapor Recovery (ORVR)



    1. When the internal pressure of the fuel tank assembly increases during refueling, the fuel vapor enters the canister. The air that has had the fuel vapor removed from it will be discharged through the fresh air line. The vent valve is used to open and close the fresh air line, and it is always open (even when the engine is stopped) except when the vehicle is in monitoring mode (the valve will remain open as long as the vehicle is not in monitoring mode). If the vehicle is refueled in system monitoring mode, the ECM will recognize the refueling by way of the canister pressure sensor, which will detect the sudden pressure increase in the fuel tank assembly, and the ECM will open the vent valve.


      W105047E01



  4. EVAP Leak Check



    1. The EVAP leak check operates in accordance with the following timing chart:


      W102532E03


      Order
      Operation
      Description
      Time
      1)
      Atmospheric Pressure Measurement
      The ECM turns the vent valve off (vent) and measures EVAP system pressure to determine the atmospheric pressure.
      10 sec.
      2)
      0.02 in. Leak Pressure Measurement
      The leak detection pump creates negative pressure (vacuum), limited by a 0.02 in. orifice and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure (reference pressure).
      360 sec.
      3)
      EVAP Leak Check
      The leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized pressure is larger than the 0.02 in. leak pressure, ECM determines that the EVAP system has a leak. If the EVAP pressure does not stabilize within 15 minutes, the ECM cancels the EVAP monitor.
      Within 15 min.
      4)
      Purge VSV Monitor
      The ECM opens the purge VSV and measures the EVAP pressure increase. If the increase is large, the ECM interprets this as normal.
      10 sec.
      5)
      Repeat 0.02 in. Leak Pressure Measurement
      The leak detection pump creates negative pressure (vacuum) limited by a 0.02 in. orifice and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure.
      60 sec.
      6)
      Final Check
      The ECM measures the atmospheric pressure and records the monitor result.
      -


CONSTRUCTION


  1. Three-Way Catalytic Converter (TWC)

    1. TWCs are provided in the front exhaust pipe assembly.



    2. This TWC enables to improve exhaust emissions.


      W104992E01


      Text in Illustration 
      *1
      1. Front Exhaust Pipe Sub-assembly
        1. TWC
      -
      -



  2. Fuel Inlet (Fresh Air Inlet)



    1. The fresh air line inlet is located the near the fuel inlet pipe opening. The fresh air from the atmosphere and drain air cleaned by the canister will go in or out of the system through the passages shown below.


      W105058E03


      Text in Illustration 
      *1
      Fuel Tank Cap Assembly
      *2
      Canister Filter
      *3
      Fuel Inlet Pipe
      -
      -
      *a
      To Canister
      -
      -
      V100135
      Fresh Air
      V100136
      Cleaned Drain Air



  3. Canister Pump Module

    1. The canister pump module consists of the vent valve, reference orifice, canister pressure sensor, leak detection pump and pump motor.

    2. The vent valve switches the passages in accordance with the signals received from the ECM.

    3. A DC type brushless motor is used for the pump motor.



    4. A vane type leak detection pump is used.


      W100075E06


OPERATION


  1. Atmospheric Pressure Measurement

    1. When the ignition switch is turned off, the purge VSV and the vent valve are turned off. Therefore, atmospheric pressure is introduced into the canister.

    2. The ECM measures the atmospheric pressure using the canister pressure sensor.



    3. If the measured atmospheric pressure is out of range, the ECM actuates the leak detection pump in order to monitor the changes in the pressure.


      W105048E01



  2. 0.02 in. Leak Pressure Measurement

    1. The purpose of this measurement is to confirm leak detection pump operation, and to provide a baseline measurement value that will be used for comparison in subsequent leak test steps.

    2. The vent valve remains off, atmospheric pressure is introduced into the canister and the ECM actuates the leak detection pump, creating a vacuum in the piping close to the canister pressure sensor.

    3. At this time, the pressure will not decrease below what is referred to as the 0.02 in. pressure due to the atmospheric pressure that enters the piping close to the pump and sensor through the 0.02 in. diameter reference orifice.

    4. The ECM compares its standard and this pressure. If the pressure is within the acceptable range, the ECM stores this pressure as the 0.02 in. leak pressure.

    5. If the pressure is below the standard, the ECM will determine that the reference orifice is clogged and store DTC P043E in its memory.



    6. If the pressure is above the standard, the ECM will determine that a high flow rate pressure is passing through the reference orifice and store DTCs P043F, P2401 and P2402 in its memory.


      W105049E02



  3. EVAP Leak Check

    1. While actuating the leak detection pump, the ECM turns the vent valve on in order to introduce a vacuum into the canister.

    2. When the pressure in the system stabilizes, the ECM compares this pressure and the 0.02 in. pressure in order to determine if a leak is present.

    3. If the detected pressure is below the 0.02 in. pressure, the ECM determines that there is no leak.

    4. If the detected pressure is above the 0.02 in. pressure and near atmospheric pressure, the ECM determines that there is a gross leak (large hole) and stores DTC P0455 in its memory.



    5. If the detected pressure is above the 0.02 in. pressure, the ECM determines that there is a small leak (minor leak) and stores DTC P0456 in its memory.


      W105050E03



  4. Purge VSV Monitor

    1. After completing an EVAP leak check, the ECM turns the purge VSV on (open) with the leak detection pump actuated, and introduces the atmospheric pressure from the intake manifold to the canister.

    2. If the pressure change at this time is within the normal range (a pressure change occurs), the ECM determines the condition to be normal.



    3. If the pressure change is out of the normal range (insufficient pressure change occurs), the ECM will stop the purge VSV monitor (purge monitor) and store DTC P0441 in its memory.


      W105051E02



  5. Repeat 0.02 in. Leak Pressure Measurement

    1. While the ECM operates the leak detection pump, the purge VSV and vent valve are turned off and a repeat 0.02 in. leak pressure measurement is performed.

    2. The ECM compares the measured pressure with the pressure during the EVAP leak check.

    3. If the pressure during the EVAP leak check is less than the repeat 0.02 in. leak pressure measurement, the ECM determines that there is no leak.



    4. If the pressure during the EVAP leak check is above the repeat 0.02 in. leak pressure measurement, the ECM determines that there is a small leak and stores DTC P0456 in its memory.


      W105052E01