EMISSION CONTROL SYSTEM (for Sedan) > DETAILS |
| FUNCTION OF MAIN COMPONENTS |
The main components of the exhaust emission control system are as follows.
| Component | Function |
| TWC | Oxidizes CO and HC in the exhaust gas and deoxidizes NOx at the same time, to purify them into CO2, H2O and N2. |
| Oxygen Sensor | The signal of the air-fuel ratio sensor changes abruptly between lean and rich at the stoichiometric air fuel ratio. Located downstream of the catalytic converter. |
| Air Fuel Ratio Sensor | Is used to determine the concentration of oxygen remaining in the exhaust gas. Has a characteristic where its output is proportional to the engine air fuel ratio. Located upstream of the catalytic converter. |
| ECM | Controls the volume of fuel consumed based primarily on the signal from the air fuel ratio sensor, with minor corrections based on the signal from the oxygen sensor. This control optimizes the exhaust emissions. |
The main components of the evaporative emission control system are as follows.
| Component | Function |
| Charcoal Canister Assembly | Contains activated charcoal to absorb the vapor gas that is created in the fuel tank. |
| Refueling Valve | Controls the flow rate of the vapor gas from the fuel tank to the canister when the system is purging or during refueling. |
| Restrictor Passage | Prevents a large amount of vacuum during purge operation or system monitoring operation from affecting the pressure in the fuel tank. |
| Fresh Air Line | Fresh air goes into the canister and the cleaned drain air goes out into the atmosphere. |
| Vent Valve | Opens and closes the fresh air line in accordance with the signals from the ECM. |
| Leak Detection Pump | Applies vacuum pressure to the EVAP control system in accordance with the signals from the ECM. |
| Canister Pressure Sensor | Detects the pressure in the EVAP control system and sends the signals to the ECM. |
| Purge VSV | Opens in accordance with the signals from the ECM when the system is purging, in order to send the vapor gas that was absorbed by the canister into the intake manifold. In the system monitoring mode, this valve controls the introduction of the vacuum into the fuel tank. |
| Canister Filter | Prevents dust and debris in the fresh air from entering the system. |
| ECM | Controls the canister pump module and purge VSV in accordance with the signals from various sensors, in order to achieve a purge volume that suits the driving conditions. In addition, the ECM monitors the system for any leakage and outputs a DTC if a malfunction is found. |
| SYSTEM CONTROL |
Purge Flow Control
When the engine has satisfied the predetermined conditions (closed loop, engine coolant temperature above 74 °C(165°F), etc.), the stored vapor gas are purged from the canister whenever the purge VSV is opened by the ECM.
The ECM will change the duty ratio cycle of the purge VSV, thus controlling purge flow volume. Purge flow volume is determined by intake manifold pressure and the duty ratio cycle of the purge VSV. Atmospheric pressure is allowed into the canister to ensure that purge flow is constantly maintained whenever purge vacuum is applied to the canister.

On-board Refueling Vapor Recovery (ORVR)
When the internal pressure of the fuel tank increases during refueling, this pressure causes the diaphragm in the refueling valve to lift up, allowing the vapor gas to enter the canister. Because the vent valve is always open (even when the engine is stopped) when the system is in a mode other than the monitoring mode, the air that has been cleaned through the canister is discharged outside the vehicle via the fresh air line. If the vehicle is refueled in the monitoring mode, the ECM will recognize the refueling by way of the canister pressure sensor, which detects the sudden pressure increase in the fuel tank, and will open the vent valve.

EVAP Leak Check
The EVAP leak check operates in accordance with the following timing chart:

| Order | Operation | Description | Time |
| 1) | Atmospheric Pressure Measurement | ECM turns vent valve off (vent) and measures EVAP control system pressure to memorize atmospheric pressure. | 10 sec. |
| 2) | 0.02 in. Leak Pressure Measurement | Leak detection pump creates negative pressure (vacuum) through 0.02 in. orifice and the pressure is measured. ECM determines this as 0.02 in. leak pressure. | 60 sec. |
| 3) | Vacuum Introduction | Leak detection pump creates negative pressure (vacuum) in EVAP control system until the pressure stabilizing and measures and memorizes the stabilizing pressure. If EVAP control system pressure does not stabilize within 12 minutes, ECM cancels EVAP monitor. | Within 12 min. |
| 4) | Purge VSV Monitor | ECM opens purge VSV and measures EVAP control system pressure increase. If increase is large, ECM interprets this as normal. | 10 sec. |
| 5) | Repeat 0.02 in. Leak Pressure Measurement | Leak detection pump creates negative pressure (vacuum) through 0.02 in. orifice and pressure is measured. ECM determines this as 0.02 in. leak pressure. ECM compares 0.02 in. leak pressure with pressure memorized in vacuum introduction, and detects any leakage. | 60 sec. |
| 6) | Final Check | ECM measures atmospheric pressure and records monitor result. | - |
| CONSTRUCTION |
Refueling Valve
The refueling valve consists of the chamber A, chamber B, and restrictor passage. A constant atmospheric pressure is applied to the chamber A.
During refueling, the internal pressure of the fuel tank increases. This pressure causes the refueling valve to lift up, allowing the vapor gas to enter the canister.
The restrictor passage prevents the large amount of vacuum that is created during purge operation or system monitoring operation from entering the fuel tank, and limits the flow of the vapor gas from the fuel tank to the canister. If a large volume of vapor gas recirculates into the intake manifold, it will affect the air fuel ratio control of the engine. Therefore, the role of the restrictor passage is to help prevent this from occurring.

| *1 | Chamber A | *2 | Chamber B |
| *3 | Canister | - | - |
| *a | During Refueling | *b | Fresh Air Line |
| *c | Refueling Valve (Open) | *d | From Fuel Tank |
| *e | Internal Pressure | *f | During Purge Operation or System Monitoring Operation |
| *g | To Fuel Tank | *h | Positive Pressure (Fuel Tank Pressure) |
| *i | Restrictor Passage | *j | Negative Pressure (Intake Manifold Pressure) |
Fuel Inlet (Fresh Air Line)
In accordance with the change of structure of the EVAP control system, the location of a fresh air line inlet has been changed from the air cleaner section to the near fuel inlet. The flesh air from the atmosphere and drain air cleaned by the canister will go in and out of the system through the passage shown below.

| *1 | Fuel Tank Cap | *2 | Fresh Air |
| *3 | Fuel Inlet Pipe | *4 | Cleaned Drain Air |
| *a | To Canister | - | - |
Canister Pump Module
Canister pump module consists of the vent valve, leak detection pump, and canister pressure sensor.
The vent valve switches the passages in accordance with the signals received from the ECM.
A DC type brushless motor is used for the pump motor.
A vane type vacuum pump is used.

| *1 | Canister Pressure Sensor | *2 | Leak Detection Pump |
| *3 | Pump Motor | *4 | Vane Pump |
| *5 | Vent Valve | - | - |
| *a | Fresh Air | *b | To Canister |

| OPERATION |
Evaporative Emission Control System
When the ignition switch is turned off, the purge VSV and vent valve are turned off. Therefore, the atmospheric pressure is introduced into the canister.
The ECM measures the atmospheric pressure through the signals provided by the canister pressure sensor.
If the measurement value is out of standards, the ECM actuates the leak detection pump in order to monitor the changes in the pressure.

0.02 in. Leak Pressure Measurement
The vent valve remains off, and the ECM introduces atmospheric pressure into the canister and actuates the leak detection pump in order to create a negative pressure.
At this time, the pressure will not decrease beyond a 0.02 in. leak pressure due to the atmospheric pressure that enters through a 0.02 in. diameter reference orifice.
The ECM compares the logic value with this pressure, and stores it as a 0.02 in. leak pressure in its memory.
If the measurement value is below the standard, the ECM will determine that the reference orifice is clogged and store Diagnostic Trouble Code (DTC) P043E in its memory.
If the measurement value is above the standard, the ECM will determine that a high flow rate pressure is passing through the reference orifice and store DTCs P043F, P2401 and P2402 in its memory.

Vacuum Introduction
While the leak detection pump is actuated, the ECM turns on the vent valve in order to introduce vacuum into the canister.
When the pressure in the system stabilizes, the ECM measures and memorizes the pressure.

Purge VSV Monitor
After completing an EVAP leak check, the ECM turns on (open) the purge VSV with the leak detection pump actuated, and introduces the atmospheric pressure from the intake manifold to the canister.
If the pressure change at this time is within the normal range, the ECM determines the condition to be normal.
If the pressure is out of the normal range, the ECM will stop the purge VSV monitor and store DTC P0441 in its memory.

Repeat 0.02 in. Leak Pressure Measurement
While the ECM operates the vacuum pump, the purge VSV and vent valve turn off and a repeat 0.02 in. leak pressure measurement is performed.
The ECM compares the measured pressure with the pressure memorized in vacuum introduction.
If the pressure memorized in vacuum introduction is below the measured value, the ECM determines that there is no leakage.
If the pressure memorized in vacuum introduction is above the measured value and near atmospheric pressure, the ECM determines that there is a gross leakage (large hole) and stores DTC P0455 in its memory.
If the pressure memorized in vacuum introduction is above the measured value, the ECM determines that there is a small leakage and stores DTC P0456 in its memory.