STARTING SYSTEM (for Sedan) > DETAILS |
| SYSTEM CONTROL |
Cranking Hold Function
As indicated in the following timing chart, when the ECM detects a start signal from the ignition switch, it energizes the starter relay to operate the starter. If the engine is already running, the ECM will not energize the starter relay.
After the starter operates and the engine speed becomes higher than approximately 500 rpm, the ECM determines that the engine has started and stops the operation of the starter.
If the engine has any failure and does not work, the starter operates as long as its maximum continuous operation time and stops automatically. The maximum continuous operation time is approximately 2 seconds through 25 seconds depending on the engine coolant temperature condition. When the engine coolant temperature is extremely low, it is approximately 25 seconds and when the engine is warmed up sufficiently, it is approximately 2 seconds.
In case that the starter begins to operate, but the engine speed signal cannot be detected, the ECM will stop the starter operation. However, if the ignition switch is held in the START position, the starter continues to operate.
Timing Chart