AIR CONDITIONING SYSTEM (for Hatchback) > DETAILS |
| FUNCTION OF MAIN COMPONENTS |
The air conditioning system consists of the following parts:
| Component | Function |
| No. 1 Heater Control Sub-assembly | Allows the air outlet to be adjusted manually and the fresh-air/recirculation mode to be selected manually. |
| No. 2 Heater Control Sub-assembly | Allows the blower control to be selected manually. |
| No. 3 Heater Control Sub-assembly | Allows the A/C switch and the MAX HOT switch to be turned on or off manually and the air outlet temperature to be adjusted manually. |
| Air Conditioning Amplifier Assembly | Transmits and receives data between the switches and sensors. |
| Compressor with Pulley Assembly | A continuously variable capacity type cooler compressor is used to steplessly control the refrigerant discharge capacity, thus improving comfort and achieving energy savings. |
| Blower with Fan Motor Assembly | High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly. |
| Cooler Condenser Assembly | A Multi-Flow (MF)-IV sub-cool condenser is used to improve heat exchange efficiency. |
| Heater Radiator Unit Sub-assembly | A Straight Flow Aluminum (SFA)-II heater radiator is used for compactness and high performance. |
| No. 1 Cooler Evaporator Sub-assembly | A Revolutionary super-Slim structure (RS) evaporator is used for compactness. |
| No. 1 Cooler Thermistor | Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly. |
| Thermistor Assembly | Detects ambient temperature and outputs it to the combination meter assembly. |
| PTC Heater (Quick Heater Assembly)* | Consists of a Positive Temperature Coefficient (PTC) element, an aluminum fin and a brass plate. |
| No. 1 Integration Relay | Adjusts the PTC heater (quick heater assembly) in 3 steps. |
| Clean Air Filter | Removes particles to provide a comfortable interior space. |
| Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly) |
|
| Air Conditioning Pressure Sensor | Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly. |
| E.F.I. Engine Coolant Temperature Sensor | Detects the engine coolant temperature and transmits it to the ECM. |
| ECM | Receives the signals from the E.F.I. engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly. |
| SYSTEM CONTROL |
Control List
The air conditioning system uses the following types of control.
| Control | Outline |
| Refrigerant Volume Detection Control | Judges a shortage of refrigerant volume based on signals from each sensor and informs the user by turning off the indicator light of the A/C switch. |
| Variable Capacity Compressor Control | Controls the compressor with pulley assembly to turn on or off and the discharge capacity based on the signals from various sensors. |
| PTC Heater Control* |
|
| Self-diagnosis | The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the memory in the form of a Diagnostic Trouble Code (DTC). |
Refrigerant Volume Detection Control
The air conditioning amplifier assembly judges the volume of refrigerant from the ambient temperature, refrigerant pressure and the temperature of the cool air past the No. 1 cooler evaporator sub-assembly. When the air conditioning amplifier assembly judges refrigerant shortage, it turns off the indicator light of the A/C switch. At that time, the compressor with pulley assembly stops operating.

PTC Heater Control
The on/off function of the PTC heater (quick heater assembly) is controlled by the air conditioning amplifier assembly in accordance with the engine coolant temperature, engine speed, air mix setting and electrical load (generator power ratio).
For example, the number of the operating PTC heater (quick heater assembly) varies with engine coolant temperature as in the graph below.

| CONSTRUCTION |
Heater Control Sub-assemblies
A rotary switch type heater control sub-assemblies is used.
5 air outlet modes are provided on the control panel. To enable finer mode settings, a positive feel is provided between the positions of these modes, thus achieving a high comfort level.

| *1 | No. 1 Heater Control Sub-assembly | *2 | No. 2 Heater Control Sub-assembly |
| *3 | No. 3 Heater Control Sub-assembly | - | - |
A control cable is used. This cable is circular, and is placed around the cable pulleys that are provided at the heater control sub-assembly and the damper.
The operation effort of the heater control sub-assembly is transmitted to the damper via the control cable, which always moves in the pulling direction. Due to the consistent action point of the pulleys, the fluctuation of the operating effort has been minimized through the use of the pulleys. These measures have ensured ease of use and have reduced the operating effort.

| *1 | Pulley | *2 | Base of Pulley |
| *3 | Control Cable | - | - |
| *a | Heater Control Sub-assembly Side | *b | Damper Side |
Air Conditioning Unit Assembly
The air conditioning unit consists of the heater radiator unit sub-assembly, No. 1 cooler evaporator sub-assembly, No. 1 cooler thermistor, PTC heater (quick heater assembly) and damper servo sub-assemblies.
A semi-center location air conditioning unit, in which the heater radiator unit sub-assembly and No. 1 cooler evaporator sub-assembly are placed in the vehicle's longitudinal direction, is used.

| *1 | No. 1 Cooler Evaporator Sub-assembly | *2 | Heater Radiator Unit Sub-assembly |
| *a | Side View | *b | Top View |
![]() | Front | - | - |
A partial recirculation system is used. This system has an air inlet control door (sub) in the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus enhancing heating performance. When the blower switch is on, the suction force of the blower fan opens this air inlet control door (sub).

| *1 | Air Inlet Control Door (Sub) | *2 | Air Inlet Control Door |
| *3 | Air Inlet Duct | - | - |
| *a | RECIRC | *b | FRESH |
| *c | To Blower Fan | - | - |
![]() | Air Flow | ![]() | Front |
No. 1 Cooler Evaporator Sub-assembly
A Revolutionary super-Slim structure (RS) evaporator is used. By placing the tanks at the top and the bottom of the No. 1 cooler evaporator sub-assembly and by using a micropore tube construction, the following effects have been achieved:

| *1 | Tank | *2 | Micropore Tube |
| *3 | Cooling Fin | - | - |
No. 1 Cooler Thermistor
The No. 1 cooler thermistor detects the temperature of the cool air immediately past the No. 1 cooler evaporator sub-assembly in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.
Heater Radiator Unit Sub-assembly
The heater radiator unit sub-assembly has been made more compact and performance has been improved by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment has been considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) has been reduced.

Blower with Fan Motor Sub-assembly
High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.
Servo Motor
In contrast to the previous type that detects the position by way of a potentiometer voltage, the pulse pattern type servo motor detects the relative position by way of the 2-bit on/off signals.
The forward and reverse revolutions of this motor are detected by way of 2 phases, A and B, which output 4 types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.

Cooler Condenser Assembly
A sub-cool condenser is used. This is a multi-flow condenser consisting of 3 portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This cooler condenser assembly uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.

| *1 | Modulator | *2 | Desiccant |
| *3 | Filter | *4 | Super-cooling Portion |
| *5 | Condensing Portion | - | - |
![]() | Gaseous Refrigerant | ![]() | Liquid Refrigerant |

Compressor with Pulley Assembly
The compressor with pulley assembly is a continuously variable capacity type with a capacity that varies in accordance with the cooling load of the air conditioning.
The compressor with pulley assembly consists of the shaft, lug plate, piston, shoe, crank chamber, cylinder and solenoid control valve.

| *1 | Shoe | *2 | Crank Chamber |
| *3 | Shaft | *4 | Lug Plate |
| *5 | Piston | *6 | Cylinder |
| *7 | Solenoid Control Valve | - | - |
A variable suction side throttle is used.

| *A | Maximum Volume of Refrigerant | *B | Controlled Volume of Refrigerant |
| *1 | Refrigerant Passage A | *2 | Inlet Chamber |
| *3 | Variable Suction Side Throttle | *4 | Crank Pressure Inlet Chamber |
| *5 | Compressor with Pulley Assembly | - | - |
| *a | High Flow | *b | Low Flow |
![]() | Crank Chamber Pressure | ![]() | Refrigerant Flow |
A Damper Limiter (DL) type air conditioning pulley is used. A cylinder-type damper is used for this compressor with pulley assembly and the torque fluctuations have been suppressed, thus making the inertia weight unnecessary. As a result, the weight of the compressor with pulley assembly has been reduced.

| *A | 5TSE10C Compressor | *B | Conventional Type Compressor |
| *1 | Damper | *2 | Inertia Weight |
Clean Air Filter
A high efficiency type clean air filter is used to remove dust and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The clean air filter is installed in the upper section of the blower with fan motor assembly.

| *1 | Blower with Fan Motor Assembly | *2 | Clean Air Filter |
| *3 | Air Filter Case | - | - |
PTC Heater (Quick Heater Assembly)
The PTC heater (quick heater assembly) is located above the heater radiator unit sub-assembly in the air conditioning unit.
The PTC heater (quick heater assembly) consists of a Positive Temperature Coefficient (PTC) element, an aluminum fin and a brass plate. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.

| *1 | PTC Element | *2 | Aluminum Fin |
| *3 | Brass Plate | - | - |
Thermistor Assembly
The thermistor assembly detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.
| OPERATION |
Mode Position and Door Operation

| Control Damper | Operation Position | Damper Position | Operation | |
| Air Inlet | FRESH | A | Brings in fresh air. | |
| RECIRCULATION | B | Recirculates internal air. | ||
| Air Mix | MAX COLD to MAX HOT | C to D | Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD. | |
| Mode | ![]() | FACE | E, J | Air blows out of the center register and side register. |
![]() | BI-LEVEL | F, J | Air blows out of the center register, side registers, and front and rear footwell register ducts. | |
![]() | FOOT | F, I | Air blows out of the front and rear footwell register ducts and side register. In addition, air blows out slightly from the front defroster and side defroster. | |
![]() | FOOT/DEF | F, H | Defrosts the windshield through the center defroster, side defroster and side register, while air is also blown out from the front and rear footwell register ducts. | |
![]() | DEF | E, G | Defrosts the windshield through the center defroster, side defroster and side register. | |
Air Outlets and Airflow Volume

| Indication | Mode | A | B | C | D |
| Center | Side | Foot | Defroster | ||
![]() | FACE | ![]() | ![]() | - | - |
![]() | BI-LEVEL | ![]() | ![]() | ![]() | - |
![]() | FOOT | - | ![]() | ![]() | ![]() |
![]() | FOOT/DEF | - | ![]() | ![]() | ![]() |
![]() | DEF | - | ![]() | - | ![]() |
Compressor Operation
The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).
The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.

| *1 | Suction Passage | *2 | Crank Chamber |
| *3 | Piston | *4 | Discharge Passage |
| *5 | Solenoid Control Valve | *6 | Air Conditioning Amplifier Assembly |
When the solenoid control valve closes (the solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.

| *1 | Suction Passage | *2 | Crank Chamber |
| *3 | Piston | *4 | Discharge Passage |
| *5 | Solenoid Control Valve | *6 | Air Conditioning Amplifier Assembly |
| *a | Crank Chamber Pressure + Spring Force | *b | Piston Stroke: Large |
When the solenoid control valve opens (the solenoid coil is not energized), the difference in pressure disappears. Then, the pressure applied to the left side of the piston becomes the same as the pressure applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lag plate. As a result, there is a small piston stroke and the discharge capacity decreases.

| *1 | Suction Passage | *2 | Crank Chamber |
| *3 | Piston | *4 | Discharge Passage |
| *5 | Solenoid Control Valve | *6 | Air Conditioning Amplifier Assembly |
| *a | Crank Chamber Pressure + Spring Force | *b | Piston Stroke: Small |
| DIAGNOSIS |
The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the air conditioning system memory in the form of DTCs. For details, refer to the Repair Manual.