Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE (for Sedan)

SPIRAL CABLE (for Sedan) > INSPECTION



1. INSPECT SPIRAL CABLE


B335036E01
  1. Check the spiral cable.

    1. Using an ohmmeter, measure the resistance between the terminals.

      1. Set the spiral cable in the center, and measure the resistance in each position where the spiral cable is turned 2.5 times clockwise and counterclockwise.
      2. Turn the spiral cable 2.5 times clockwise from its original position and measure the resistance while turning it 5 times counterclockwise.

      Standard resistance:
      Tester Connection
      Specified Condition
      A1(D-) - D2(D-)
      Below 1 Ω
      A2(D+) - D1(D+)
      Below 1 Ω
      B1(D2-) - D3(D2-)
      Below 1 Ω
      B2(D2+) - D4(D2+)
      Below 1 Ω

      NOTICE:
      To avoid breakage of the spiral cable, do not turn the spiral cable more than necessary. If the result is not as specified, replace the spiral cable.