AIR CONDITIONING PRESSURE SENSOR (for Sedan) > ON-VEHICLE INSPECTION |
| 1. INSPECT PRESSURE SENSOR |
![]() |
Check the wire harness.
Disconnect the connector of the pressure sensor.
Using an ohmmeter, measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| 1 - Body ground | Below 1 Ω |
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| 1 - 3 | 4.7 to 5.3 V |
![]() |
Check the pressure sensor.
Set the manifold gauge.
Connect the connector to the pressure sensor.
Warm up the engine.
Switch A/C ON.
Using a voltmeter, measure the voltage between connector terminals 6 (PRE) and 11 (SG-1) of the air conditioner amplifier.
| Refrigerant Pressure | Specified Condition |
| 196 to 3140 kPa (2.0 to 32.0 kgf/cm2, 28 to 455 psi) | 0.76 to 4.74 V |