DTC    P0711    Transmission Fluid Temperature Sensor "A" Performance


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input to the ECM.
The sensor resistance changes with the transmission fluid temperature. As the temperature rises, the sensor resistance decreases. The ECM applies a voltage to the temperature sensor through ECM terminal THO1, and the ECM calculates the fluid temperature based on the voltage signal.

HINT:
  1. The ATF temperature is likely to increase under conditions such as towing, climbing hills and in traffic.
  2. When the ATF temperature sensor is normal, the transmission locks up in 4th gear with the shift lever in D and in 3rd gear with the shift lever in 3.


DTC No.
DTC Detection Condition
Trouble Area
P0711
One of the following conditions (A), (B), (C) or (D) is met:
  1. ATF level
  2. Transmission wire (ATF temperature sensor)
Condition (A):
(a), (b) and (c) are detected: (2-trip detection logic).
(a) After normal driving for 18 minutes and 20 seconds and 9 km (5.6 miles) or more.
(b) Intake air and engine coolant temperature are -10°C (14°F) or more at 12 seconds after engine start.
(c) ATF temperature is less than 10°C (50°F)
Condition (B):
(a), (b) and (c) are detected: (2-trip detection logic).
(a) After normal driving for 30 minutes and 15 km (9.3 miles) or more.
(b) Intake air and engine coolant temperature are -15°C (5°F) or more at 12 seconds after engine start.
(c) ATF temperature is less than 10°C (50°F)
Condition (C):
Both (a) and (b) are detected: (2-trip detection logic).
(a) After normal driving for 40 minutes and 20 km (12.4 miles) or more.
(b) ATF temperature is less than 10°C (50°F)
Condition (D):
Both (a) and (b) are detected: (2-trip detection logic).
(a) Engine coolant temperature is less than 35°C (95°F) at 12 seconds after engine start.
(b) ATF temperature is 100°C (212°F) or more.

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects opens or shorts in the ATF temperature circuit or a fault of the ATF temperature sensor.
After running the vehicle for a certain period, the ATF temperature should increase. If the ATF temperature is below 10°C (50°F) after running the vehicle for a certain period, the ECM interprets this as a fault, and turns on the MIL and stores the DTC.
When the ATF temperature is 100°C (212°F) or more and engine coolant temperature reaches 60°C (140°F) after cold start, the ECM also determines this as a fault, turns on the MIL, and stores the DTC.

INSPECTION PROCEDURE


DATA LIST

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the Techstream to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn the Techstream on.

  6. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data.

  7. In accordance with the display on the Techstream, read the Data List.

    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    ATF Temperature Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test; Approximately 80°C (176°F)
    2. Equal to ambient temperature when cold soak
    If value is -40°C (-40°F) or 150°C (302°F) or more, ATF temperature sensor circuit is open or short.

    HINT:
    When DTC P0712 is output and Techstream reading is 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and Techstream reading is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THO1 and the body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF (Automatic Transmission Fluid) temperature sensor becomes open, P0713 is immediately set (within 0.5 seconds).
    It is not necessary to inspect the circuit when P0711 is set.

1.CHECK OTHER DTCS OUTPUT (IN ADDITION TO DTC P0711)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read the DTCs using the Techstream.
    Result 
    Result
    Proceed to
    Only P0711 is output
    A
    P0711 and other DTCs are output
    B

    HINT:
    If any DTCs codes besides P0711 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.CHECK TRANSMISSION FLUID LEVEL

OK:
Automatic transmission fluid level is correct.



NG
ADD FLUID
OK

REPLACE TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) (Click here)