CONDENSER (for Sedan) > INSTALLATION |
| 1. INSTALL CONDENSER |
![]() |
Engage the 2 claws and install the condenser into the vehicle.
| 2. INSTALL LIQUID TUBE SUB-ASSEMBLY A |
![]() |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring onto the liquid tube.
Install the liquid tube onto the cooler condenser with the bolt.
| 3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring onto the discharge hose.
Install the discharge hose onto the cooler condenser with the bolt.
| 4. INSTALL RADIATOR SUPPORT SUB-ASSEMBLY UPPER |
![]() |
Install the radiator support sub-assembly upper with the 4 bolts.
Connect the horn assembly connector.
| 5. INSTALL HOOD LOCK ASSEMBLY (w/ Theft Deterrent System) |
![]() |
Temporarily install the hood lock assembly with the 3 bolts.
Connect the engine hood courtesy switch connector.
![]() |
Connect the hood lock control cable assembly to the 2 clamps.
| 6. INSTALL HOOD LOCK ASSEMBLY (w/o Theft Deterrent System) |
![]() |
Temporarily install the hood lock assembly with the 3 bolts.
![]() |
Connect the hood lock control cable assembly to the 2 clamps.
| 7. INSTALL NO. 1 COOLER COVER |
![]() |
Insert the 2 pins of No. 1 cooler cover into the radiator support LWR.
Install No. 1 cooler cover with the 2 clips.
| 8. INSTALL FRONT BUMPER COVER |
| 9. ADJUST HOOD LOCK ASSEMBLY |
![]() |
Loosen the hood side hinge bolts.
Move the hood to adjust the clearance to within the standard range.
Tighten the hood side hinge bolts after the adjustment.
![]() |
Adjust the height of the hood front end by turning the cushion rubber.
![]() |
Adjust the hood lock.
Loosen the 3 bolts.
Adjust the hood lock position so that the striker can enter it smoothly.
Tighten the 3 bolts after the adjustment.
| 10. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 11. WARM UP ENGINE |
| 12. CHECK FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially the connection points, for leakage.
![]() |
Bring the halogen leak detector close to the drain hose before performing the test.
If a gas leak is not detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.