LIGHTING SYSTEM (for Hatchback) > Daytime Running Light Relay Circuit |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Active Test.
According to the display on the Techstream, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Daytime Running Light | Running light relay | OFF or ON | - |
|
| ||||
| OK | ||
| ||
| 2.CHECK HEADLIGHT |
Check the operation of the low beam headlights.
|
| ||||
| OK | |
| 3.INSPECT RUNNING LIGHT RELAY |
![]() |
Remove the running light relay from the No. 2 engine room relay block.
Connect a positive (+) lead from the battery to terminal 6 (+B).
Connect a negative (-) lead from the battery to terminal 2 (DRLS) and 3 (E).
Check for pulses according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (HLOR) - Battery negative terminal | Always | Pulse generation |
| 5 (HLOL) - Battery negative terminal | Always | Pulse generation |
| *a | Component without harness connected (Running Light Relay) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (RUNNING LIGHT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Remove the running light relay from the No. 2 engine room relay block assembly.
Disconnect the 3C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| DRL-2 (DRLS) - 3C-22 | Always | Below 1 Ω |
| DRL-2 (DRLS) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly.
Remove the main body ECU from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
| 3C-22 - MB-25 (DRL) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||