OCCUPANT CLASSIFICATION SYSTEM (for Sedan) > INITIALIZATION |
| ZERO POINT CALIBRATION |
Zero point calibration procedures:
Check that all of the following conditions are met:
Adjust the seat position in accordance with the table below.
| Adjustment Item | Position |
| Slide Direction | Rearmost position |
| Reclining Angle | Upright position |
| Headrest Height | Lowest position |
| Lifter Height | Lowest position |
Connect a Techstream to the DLC3.
Turn the ignition switch to ON.
Perform the zero point calibration by following the prompts on the tester screen.
| SENSITIVITY CHECK |
Sensitivity check procedures:
Connect a Techstream to the DLC3.
Turn the ignition switch ON.
Perform the sensitivity check by following the prompts on the tester screen.
Confirm that the beginning sensor reading is within the standard range.
Place a 30 kg (66.2 lb) weight (e.g. a lead mass) onto the front passenger seat.
Confirm that the sensitivity is within the standard range.