Home
›
Drivetrain · U340E AUTOMATIC TRANSMISSION / TRANSAXLE
›
TRANSMISSION WIRE (for Sedan)
TRANSMISSION WIRE (for Sedan) > INSPECTION
1. INSPECT TRANSMISSION WIRE
Measure the resistance.
Standard resistance:
Tester Connection
Oil Temperature
Specified Condition
1(OT+) - 6(OT-)
10°C (50°F)
6.4 kΩ
1(OT+) - 6(OT-)
110°C (230°F)
0.2 kΩ