DTC C1524/24 Motor Circuit Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| C1524/24 | Short (or open) in motor circuit or abnormal voltage or current in motor circuit. |
|

| 1.READ VALUE USING TECHSTREAM |
Connect a Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Chassis / EMPS / Data List.
Select the item "Motor Actual Current" and "Command Value Current" in the Data List and read the value displayed on the Techstream.
| Data List Item | Steering Position (Left Turned) | Steering Position (Center) | Steering Position (Right Turned) |
| Motor Actual Current | 10 A to 55 A | -1 A to +1 A | -55 A to -10 A |
| Command Value Current | 55 A | 0 A | -55 A |
|
| ||||
| NG | |
| 2.INSPECT POWER STEERING ECU |
![]() |
Turn the ignition switch to ON.
Measure the voltage.
| Tester Connection | Condition (Steering Position) | Specified Condition |
| M1 (b1-1) - PGND (A19-2) | Turned to right | Below 1 V |
| M1 (b1-1) - PGND (A19-2) | Turned to left | 11 to 14 V |
| M2 (b1-2) - PGND (A19-2) | Turned to right | 11 to 14 V |
| M2 (b1-2) - PGND (A19-2) | Turned to left | Below 1 V |
|
| ||||
| NG | |
| 3.CHECK HARNESS AND CONNECTOR (POWER STEERING ECU - BODY GROUND) |
![]() |
Disconnect the connector from the power steering ECU.
Measure the resistance and the voltage.
| Tester Connection | Condition | Specified Condition |
| PGND (A19-2) - Body ground | Always | Below 1 Ω |
| PIG (A19-1) - Body ground | Ignition switch on. | 11 to 14 V |
|
| ||||
| OK | |
| 4.INSPECT STEERING COLUMN ASSEMBLY (POWER STEERING MOTOR) |
![]() |
Disconnect the connector from the power steering ECU.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| M1 (b1-1) - M2 (b1-2) | Always | 0.08 to 0.15 Ω |
| M1 (b1-1) - Body ground | Always | 1 MΩ or higher |
| M2 (b1-2) - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||