Home › Engine / Hybrid System › 1NZ-FE ENGINE CONTROL › INTEGRATION RELAY (for Sedan)

INTEGRATION RELAY (for Sedan) > INSPECTION



1. INSPECT INTEGRATION NO.1 RELAY


A203385E01
  1. Inspect the EFI fuse.

    1. Disconnect the fuse.
      Text in Illustration 
      *1
      Fuse Side
      *2
      EFI fuse

    2. Measure the resistance of the fuse.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      EFI fuse
      Always
      Below 1 Ω



    A201116E03
  1. Inspect the EFI relay.

    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Component without harness connected
      (Integration Relay)

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      C1 - A4
      Battery voltage not applied
      10 kΩ or higher
      Battery voltage applied to terminals A2 and A3
      Below 1 Ω
      C1 - A1
      Always
      Below 1 Ω

      NOTICE:
      While using the battery for the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      If the result is not as specified, replace the integration relay.



    A201116E03
  1. Inspect the FAN NO.1 relay.

    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Component without harness connected
      (Integration Relay)

      Standard Resistance:
      Tester Connection
      Condition
      Resistance
      B5 - B8
      Battery voltage not applied
      10 kΩ or higher
      Battery voltage applied to terminals B6 and B7
      Below 1 Ω

      NOTICE:
      While using the battery for the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      If the result is not as specified, replace the integration relay.



    A203385E02
  1. Inspect the AM2 fuse.

    1. Disconnect the fuse.
      Text in Illustration 
      *1
      Fuse Side
      *2
      AM2 fuse

    2. Measure the resistance of the fuse.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      AM2 fuse
      Always
      Below 1 Ω



    A201116E03
  1. Inspect the IG2 relay.

    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Component without harness connected
      (Integration Relay)

      Standard Resistance:
      Tester Connection
      Condition
      Resistance
      C1 - B4
      Battery voltage not applied
      10 kΩ or higher
      Battery voltage applied to terminals B2 and B3
      Below 1 Ω
      C1 - B1
      Always
      Below 1 Ω

      If the result is not as specified, replace the integration relay.



    B138430E01
  1. Inspect the horn relay.

    1. Remove the horn fuse.

    2. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      A8 - T6
      10 kΩ or higher
      Below 1 Ω
      (Battery voltage applied to terminals A7 and T6)

      If the result is not as specified, replace the integration relay.