Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Sedan)

AIR CONDITIONING SYSTEM (for Sedan) > TERMINALS OF ECU



CHECK AIR CONDITIONING AMPLIFIER

E265380E01

HINT:
Check from the rear of the connector while it is connected to the air conditioning amplifier.


Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
S5-3 (E8-1) - GND (E8-12)
Y - W-B
Power supply for pressure sensor
Ignition switch: ON
4.5 to 5.5 V
TX+ (E8-2) - GND (E8-12)
V - W-B
CAN communication line
Ignition switch: ON
Pulse generation
(see waveform 1)
TX- (E8-3) - GND (E8-12)
W - W-B
CAN communication line
Ignition switch: ON
Pulse generation
(see waveform 2)
SG-2 (E8-4) - Body ground
L - Body ground
Ground for evaporator temperature sensor
Always
Below 1.0 Ω
TAM (E8-5) - SG-1 (E8-11)
W - B
Ambient temperature sensor signal
Ignition switch: ON
1.35 to 1.75 V
Ambient temperature: 25 °C
PRE (E8-6) - SG-1 (E8-11)
GR - B
A/C pressure sensor signal
Refrigerant pressure: normal
0.76 to 4.74 V
PRE (E8-6) - SG-1 (E8-11)
GR - B
A/C pressure sensor signal
Refrigerant pressure: abnormal
(less than 196 kPa [2.0 kgf/cm2, 28 psi] or more than 3140 kPa [32.0 kgf/cm2, 455 psi])
Below 0.76 V or 4.74 V or more
SOL+ (E8-7) - GND (E8-12)
LG - W-B
A/C compressor operation signal
Engine idling
Pulse generation
(see waveform 3)
Blower switch: 1
A/C switch: ON
IG+ (E8-8) - GND (E8-12)
Y - W-B
Power source (IG)
Ignition switch: ON
11 to 14 V
SBLW (E8-9) - GND (E8-12)
BR - W-B
Blower motor ON signal
Ignition switch: ON
11 to 14 V → 0 V
Blower switch: 0 → 1
TE (E8-10) - SG-2 (E8-4)
GR - L
Evaporator temperature sensor signal
Ignition switch: ON
1.0 to 1.3 V
Temperature near evaporator: 15°C (59°F)
SG-1 (E8-11) - Body ground
B - Body ground
Ground for ambient temperature sensor
Always
Below 1.0 Ω
GND (E8-12) - Body ground
W-B - Body ground
Ground for main power supply
Always
Below 1.0 Ω
A/C (E8-15) - GND (E8-12)
LG - W-B
A/C switch signal
Ignition switch: ON
Below 1 V → 11 to 14 V
Defroster: OFF
A/C switch: OFF → ON
Defroster mode detection switch signal
Ignition switch: ON
Below 1 V → 11 to 14 V
A/C switch: OFF
Defroster: OFF → ON
LED (E8-16) - Body ground
P - Body ground
A/C switch indicator signal
Engine idling
11 to 14 V → Below 4 V
A/C switch: ON
Blower switch: 0 → 1


    A086154E01
  1. Waveform 1 (Reference) : Using an oscilloscope
    CAN communication signal 
    Terminal Name
    Between TX+ (E8-2) - GND (E8-12)
    Tester Range
    1 V / DIV., 10 μsec. / DIV.
    Condition
    Ignition switch ON

    HINT:
    The waveform varies depending on the CAN communication signal.



  2. A086155E01
  3. Waveform 2 (Reference) : Using an oscilloscope
    CAN communication signal 
    Terminal Name
    Between TX- (E8-3) - GND (E8-12)
    Tester Range
    1 V / DIV., 10 μsec. / DIV.
    Condition
    Ignition switch ON

    HINT:
    The waveform varies depending on the CAN communication signal.



  4. E074977E10
  5. Waveform 3 (Reference) : Using an oscilloscope
    Compressor and pulley operation signal 
    Terminal Name
    Between SOL+ (E8-7) - GND (E8-12)
    Tester Range
    5 V / DIV., 500 μsec. / DIV.
    Condition
    Engine idling, Blower switch 1, A/C switch ON