DTC B1451/51 Compressor Solenoid Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1451/51 | Open or short in solenoid of externally changeable compressor circuit |
|

| 1.READ VALUE USING TECHSTREAM (REGULATOR CONTROL CURRENT) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Select the following menus: Body Electrical / Air Conditioner / Data List /
According to the display on tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Regulator Control Current | Regulator control current / Min.: 0 A Max.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with compressor and pulley operation | - |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT COMPRESSOR AND PULLEY |
![]() |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-1 - C8-2 | 10.1 to 11.1 Ω at 25°C (77°F) |
Reconnect the compressor and pulley connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the C8 compressor and pulley connector.
Disconnect the E8 air conditioning amplifier connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-1 - E8-7 (SOL+) | Below 1 Ω |
| C8-1 - Body ground | 10 kΩ or higher |
Reconnect the compressor and pulley connector.
Reconnect the air conditioning amplifier connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - BODY GROUND) |
![]() |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-2 - Body ground | Below 1 Ω |
Reconnect the compressor and pulley connector.
|
| ||||
| OK | ||
| ||