AIR CONDITIONING SYSTEM (for Sedan) > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
Warm up the engine.
Turn the ignition switch to OFF.
Connect the Techstream to the DLC3.
Turn the ignition switch ON.
Turn the tester on.
Enter the following menus: Body Electrical / Air Conditioner / Data List /
According to the display on tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Ambient Temperature Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Engine Coolant Temperature | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed after engine warmed up | - |
| Adjusted Ambient Temp | Adjusted ambient temperature Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | - | Open in circuit: -30.8°C (-23.44°F) Short in circuit: 50.8°C (123.44°F) |
| Evaporator Fin Thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: 0 kgf / cm2G Max.: 38.25 kgf / cm2G | Actual regulator pressure is displayed | - |
| Regulator Control Current | Regulator control current / Min.: 0 A Max.: 0.997 A | - | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 100 | Number of DTCs displayed | - |
| PERFORM ACTIVE TEST |
Connect the Techstream to the DLC3.
Turn the ignition switch ON.
Turn the tester on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test /
According to the display on tester, perform the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Magnetic Clutch Relay | Magnetic clutch relay | OFF/ON | - |