FRONT DOOR LOCK (for Sedan) > INSPECTION |
| 1. INSPECT FRONT DOOR LOCK ASSEMBLY LH |
![]() |
w/ Power door lock:
Check the operation.
Apply battery voltage to the front door lock and check the operation of the front door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 1 | Locks |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 4 | Unlocks |
Check the resistance of the unlock detection switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
| Tester Connection | Door Lock Condition | Specified Condition |
| 7 - 8 | Locked | 10 kΩ or higher |
| 7 - 8 | Unlocked | Below 1 Ω |
![]() |
Check the resistance of the door lock and unlock switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
| Tester Connection | Door Lock Condition | Specified Condition |
| 7 - 9 | Locked | Below 1 Ω |
| 7 - 9 | Unlocked | 10 kΩ or higher |
| 7 - 10 | Locked | 10 kΩ or higher |
| 7 - 10 | Unlocked | Below 1 Ω |
| 2. INSPECT FRONT DOOR LOCK ASSEMBLY RH |
![]() |
w/ Power door lock:
Check the operation.
Apply battery voltage to the front door lock and check the operation of the front door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 1 | Locks |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 4 | Unlocks |
Check the resistance of the unlock detection switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
| Tester Connection | Door Lock Condition | Specified Condition |
| 7 - 8 | Locked | 10 kΩ or higher |
| 7 - 8 | Unlocked | Below 1 Ω |
![]() |
Check the resistance of door lock and unlock switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
| Tester Connection | Door Lock Condition | Specified Condition |
| 6 - 8 | Locked | Below 1 Ω |
| 6 - 8 | Unlocked | 10 kΩ or higher |
| 5 - 8 | Locked | 10 kΩ or higher |
| 5 - 8 | Unlocked | Below 1 Ω |