GENERATOR (for Hatchback) > INSPECTION |
| 1. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the length of the exposed brushes.
| *a | Length |
| 2. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check the generator rotor for open circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Slip ring | 20°C (68°F) | 1.7 to 2.1 Ω |
| *1 | Slip Ring |
![]() |
Check the generator rotor for short circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Rotor | Always | 10 MΩ or higher |
| *1 | Slip Ring |
| *2 | Rotor |
![]() |
Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
![]() |
Using a vernier caliper, measure the slip ring diameter.
| *a | Diameter |
![]() |
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
| 3. INSPECT GENERATOR DRIVE END FRAME ASSEMBLY |
![]() |
Inspect the stator coil for open circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Coil lead - Coil lead | Always | Below 1 Ω |
| *1 | Ohmmeter |
![]() |
Inspect the stator coil for ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Coil lead - Generator drive end frame assembly | Always | 10 kΩ or higher |
| *1 | Ohmmeter |
![]() |
Inspect the generator drive end frame bearing.
Check that the bearing is not rough or worn.
If necessary, replace the generator assembly.
| 4. INSPECT GENERATOR HOLDER WITH RECTIFIER |
![]() |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P1, P2, P3 and B | Always | Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
| P1, P2, P3 and E | Always | Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
| 5. INSPECT GENERATOR REGULATOR ASSEMBLY |
Check the resistance.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminals F - Terminals B | Always | When the positive and negative poles between terminals F and B are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminals E - Terminals F | Always | When the positive and negative poles between terminals E and F are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |