Home › General › SPECIFICATIONS › HEATING / AIR CONDITIONING (for Sedan)

HEATING / AIR CONDITIONING (for Sedan) > SERVICE DATA



Refrigerant charge volume
330 to 390 g (11.64 to 13.76 oz.)
Blower resistor
1 - 4 : 3.12 to 3.60 Ω
3 - 4 : 1.45 to 1.67 Ω
2 - 4 : 0.52 to 0.60 Ω
Compressor and pulley
10.1 to 11.1 Ω at 25 °C (77°F)
Heater blower motor relay
3 - 4 : Below 1Ω
3 - 4 : 10kΩ or higher (Apply battery voltage to terminals 1 and 2)
3 - 5 : 10kΩ or higher
3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)

for Manual transaxle 
Idling speed
Switch A/C OFF
550 to 650 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm

for Automatic transaxle 
Idling speed
Switch A/C OFF
650 to 750 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm