HEATING / AIR CONDITIONING (for Sedan) > SERVICE DATA |
| Refrigerant charge volume | 330 to 390 g (11.64 to 13.76 oz.) |
| Blower resistor | 1 - 4 : 3.12 to 3.60 Ω 3 - 4 : 1.45 to 1.67 Ω 2 - 4 : 0.52 to 0.60 Ω |
| Compressor and pulley | 10.1 to 11.1 Ω at 25 °C (77°F) |
| Heater blower motor relay | 3 - 4 : Below 1Ω 3 - 4 : 10kΩ or higher (Apply battery voltage to terminals 1 and 2) 3 - 5 : 10kΩ or higher 3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2) |
| Idling speed Switch A/C OFF | 550 to 650 rpm |
| Idling speed Switch A/C ON (A/C Lo → Hi) | 700 → 850 rpm |
| Idling speed Switch A/C OFF | 650 to 750 rpm |
| Idling speed Switch A/C ON (A/C Lo → Hi) | 700 → 850 rpm |