Home › Engine / Hybrid System › 2NZ-FE ENGINE CONTROL › SFI SYSTEM › 2013.08–2016.10
NM30M0E _51 Engine / Hybrid System _018293 2NZ-FE ENGINE CONTROL _0090361 SFI SYSTEM DE DETAILS F

2NZ-FE ENGINE CONTROL  SFI SYSTEM  DETAILS  COOLING FAN CONTROL  


OPERATION


a.

The ECM controls the operation of the cooling fan in 2 speeds (low and high) based on the E.F.I. engine coolant temperature sensor signal and the air conditioning amplifier assembly signal. The low speed operation is accomplished by applying the current through a resistor, which reduces the speed of the cooling fan.

W111018E01
0.469,0.885 1.833,1.313 1.365,0.427 10 false E.F.I. Engine Coolant Temperature Sensor 0.469,2.375 2.042,2.792 1.573,0.417 10 false Air Conditioning Amplifier Assembly 3.531,1.844 3.906,2.208 0.375,0.365 10 false ECM 4.656,0.198 5,0.406 0.344,0.208 10 false IG1 5.24,0.188 5.76,0.396 0.521,0.208 10 false Battery 5.375,0.99 6.688,1.313 1.313,0.323 10 false Cooling Fan Relay 5.344,1.635 6.594,1.958 1.25,0.323 10 false Cooling Fan Motor 5.427,2.219 6.99,2.563 1.563,0.344 10 false No. 2 Cooling Fan Relay 5.521,2.969 6.917,3.292 1.396,0.323 10 false Cooling Fan Resistor 3.26,3.188 4.677,3.49 1.417,0.302 10 false No. 1 Pressure Switch

Engine Coolant Temperature Cooling Fan Drive Request Signal Cooling Fan Operation
Low Off Off
Low Low
High High
High Off High
Low High
High High