Home › Engine / Hybrid System › 1NZ-FE ENGINE CONTROL › SFI SYSTEM › 2014.03–2016.07
NM30M0E _51 Engine / Hybrid System _018284 1NZ-FE ENGINE CONTROL _0090360 SFI SYSTEM DE DETAILS F

1NZ-FE ENGINE CONTROL  SFI SYSTEM  DETAILS  OXYGEN SENSOR  


CONSTRUCTION


a.

Models without Air Fuel Ratio Sensor

i.

The cup type oxygen sensor contains a sensor element that surrounds the heater.


ii.

The output voltage of the oxygen sensor changes in accordance with the oxygen concentration in the exhaust emission. The ECM uses this output voltage to determine whether the present air fuel ratio is richer or leaner than the stoichiometric air fuel ratio.

W111012C01
4.573,1.802 4.573,1.448 false 4.729,1.802 4.729,1.448 false 4.594,2.969 4.594,2.698 true 4.76,2.969 4.76,2.708 true 4.396,2.625 3.969,2.625 true 4.49,1.271 4.802,1.427 0.313,0.156 10 false *1 4.656,1.281 4.969,1.438 0.313,0.156 10 false *2 4.521,3.021 4.833,3.177 0.313,0.156 10 false *3 3.802,2.531 4.115,2.688 0.313,0.156 10 false *4 4.708,3.01 5.021,3.167 0.313,0.156 10 false *3
*1 Heater *2 Atmosphere
*3 Platinum Electrode *4 Sensor Element (Zirconia)