Home › Drivetrain › K312 CVT › CVT SYSTEM › from 2016.04
NM30M0E _52 Drivetrain _052301 K312 CVT _0252107 CVT SYSTEM DE DETAILS F

K312 CVT  CVT SYSTEM  DETAILS  SHIFT SOLENOID VALVE  


CONSTRUCTION


a.

The functions of each solenoid valve are outlined in the table below.

Solenoid Valve Type Function
On-off Solenoid Valve SC
(for Clutch)
2-way Used to switch control of the linear solenoid valve SLU for forward and reverse clutch control.
On-off Solenoid Valve SL
(for Lock-up)
2-way Used to switch control of the linear solenoid valve SLU for lock-up clutch control.
Linear Solenoid Valve SLS
(for Secondary Pulley Control)
Linear Controls the oil pressure of the secondary pulley.
Linear Solenoid Valve SLP
(for Primary Pulley Control)
Linear Controls the oil pressure of the primary pulley.
Linear Solenoid Valve SLU
(for Lock-up Control)
Linear Performs forward and reverse clutch control or lock-up clutch control depending on the state of the on-off solenoid valves SC and SL.