CONSTRUCTION
The transmission valve body assembly consists of the upper valve body, rear upper valve body, lower valve body and 5 solenoid valves.
| *1 | Rear Upper Valve Body | *2 | Upper Valve Body |
| *3 | Linear Solenoid Valve SLU | *4 | Duty Solenoid Valve DS2 |
| *5 | Lower Valve Body | *6 | Duty Solenoid Valve DS1 |
| *7 | Linear Solenoid Valve SLT | *8 | Linear Solenoid Valve SLS |
| *1 | Transmission Revolution Sensor (NIN) | *2 | Transmission Revolution Sensor (NT) |
| *3 | Primary Pulley | *4 | Secondary Pulley |
| *5 | Transmission Revolution Sensor (NOUT) | *6 | Valve Body |
| *7 | Manual Valve | *8 | Duty Solenoid Valve DS1 |
| *9 | Duty Solenoid Valve DS2 | *10 | Linear Solenoid Valve SLS |
| *11 | Linear Solenoid Valve SLU | *12 | Linear Solenoid Valve SLT |
| *13 | ECM | - | - |
| *a | Vehicle Speed Control | *b | Belt Clamping Pressure Control |
| *c | ON-OFF and Back Pressure Control | *d | Clutch Pressure Control |
OPERATION
Belt Clamping Force Control
The pulley and belt unit transmits the torque via the belt between the pulleys. The belt clamping force control generates the steel belt clamping force necessary to transmit the torque by controlling the oil pressure of the secondary pulley.
The transmission valve body assembly is provided with a dedicated hydraulic pressure circuit for belt clamping pressure control. This circuit optimally controls the hydraulic pressure applied to the secondary pulley, thus achieving superior torque transmission performance.
| *1 | Oil Pump Assembly | *2 | No. 3 Line Pressure Modulator Valve |
| *3 | Primary Regulator Valve | *4 | Clutch Apply Control Valve |
| *5 | Linear Solenoid Valve SLS | *6 | No. 1 Line Pressure Modulator Valve |
| *7 | Linear Solenoid Valve SLT | *8 | Primary Pulley |
| *9 | Secondary Pulley | - | - |
Speed Ratio Control (Shift Control)
The CVT shift mechanism controls the oil inflow/outflow from the primary pulley in the pulley and steel belt unit and continuously varies the speed ratio (pulley ratio).
Separate hydraulic circuits are provided for acceleration (fluid inflow) and deceleration (fluid outflow) in order to provide fine-tuned control and a high level of reliability.
| *1 | Duty Solenoid Valve DS2 | *2 | Duty Solenoid Valve DS1 |
| *3 | Bypass Valve | *4 | No. 1 Ratio Control Valve (Acceleration Control) |
| *5 | No. 2 Ratio Control Valve (Deceleration Control) | *6 | Primary Pulley |
| *7 | Secondary Pulley | - | - |